508-4C / 4-Ch, 6 Amp Current Generators w/ Resistance Measurement
Model 508 most capable current generator, the 508 series provides users with the ability to generate highly precise current pulses, making this unit ideal for applications that require a high level of accuracy and repeatability. Advanced safety features provide user assurance.
- Description
- Additional information
- OVERVIEW
- SPECIFICATIONS
Description
MODEL 508-4C / 4-Ch, 6 Amp Current Generators w/ Resistance Measurement
MODEL 508-4C most capable current generator provides users with the ability to generate highly precise current pulses, making this unit ideal for applications that require a high level of accuracy and repeatability. Advanced safety features provide user assurance.
The Model 508 is designed for airbag and pyrotechnic initiator testing and represents the latest in current pulse generating capabilities with compelling features that provide users with time-saving characteristics of adjustability, simple operation and programmability.
The 508 comes in a 19” 2U form factor as a 2 or 4 channel model with current sensing and resistance measurement capabilities. This unit is ideal for applications that require a high level of accuracy and repeatability.
The 508 also comes with advanced safety and testing capabilities that include remote interlock, pre and post measurements and keyed enable switch so the unit fires only when all safety criteria are met. High functionality, safety and a rapid return-on-investment are the hallmarks of this new fireset for pyrotechnic initiators. The Model 508 provides multiple firing channels: all-fire, no-fire, resistance measurement, DC current, capacitor discharge, Bruceton, Neyer, and high current.
The performance and advanced features of the 508 current pulse generator make it ideal for applications such as air bag deployment testing (squib detonation) or igniter deployment that can be done reliably, safely and with repeatability.
Applications such as air bag deployment testing (squib detonation), igniter triggering or ballistics work can be done reliably, safely and with a high level of repeatability.
Additional information
Dimensions | 25.4 × 48.26 × 8.89 cm |
---|
FEATURES
- 200 ns Timing Steps
- 6 amps per Channel
- 2 or 4 Channel Outputs
- Benchtop or Rack Mount Design
- Easy Programming Interface
- TTL Sync output to T0
- Safety Interlock
ADVANCED FEATURES
- Integrated 4-wire resistance measurement for each channel with pre and post testing features. Ability to set the mean and upper/ lower limits to determine what construes a resistance fault
- Current and voltage monitor outputs.
- Front and rear sync outputs.
- Safety features including remote interlock and removable keyed enable switch.
- RS232, USB, and Ethernet* computer programming interfaces (* Ethernet is an upgrade option)
I/O CONFIGURATION
Output Modules | 2 Output Channels4 Output Channels |
Input Module | Front and Rear Trigger |
INTERNAL RATE GENERATOR
Rate | 0.01Hz to 100 KHz |
Resolution | 100 ns |
Accuracy | 20 ns |
Jitter | 10 ns RMS |
Burst Mode | 1 to 250 pulses |
Output Modes | Single Pulse, Burst |
Control Modes | Internal Rate Generator, External Trigger |
EXTERNAL TRIGGER INPUTS
Function | Generate individual pulses (single shot or burst) |
Front or Rear | Selectable between front or rear panel inputs |
Rate | DC to 1/(330ns+Longest active pulse) |
Insertion Delay | 330 ns |
Jitter | 10ns |
Impedance | 1K |
Slope | Rising or Falling |
Trigger Filter | Filters out unwanted “glitch” or “runt” pulses |
Range | 0.02 us to 1 ms |
Resolution | 0.02 us |
Trigger Level | 2-15V |
Level Threshold Resolution | 100mV |
OUTPUTS
Amplitude | 0.10 – 6A |
Resolution | 1mA |
Accuracy | 2mA Typical |
Compliance Voltage Level | 20V |
Slew Rates | |
---|---|
Rising Edge – Inductive (Varies with Load) | 2A/ us @ 6A1A/ us @ 3A
0.30A/ us @1A< (1 ohm and 50′ cable) |
Falling Edge – Inductive (Varies with Load) | -1.60A/ us @6A-0.90A/ us @3A
-0.30A/ us @1A (1 ohm and 50′ cable) |
Rising Edge – Resistive (Varies with Load) | 6.3A/ us @6A9.5A/ us @3A
2.2A/ us @1A (1 ohm & 2″ cable) |
Falling Edge – Resisitive (Varies with Load) | -5.2A/ us @6A-4.0A/ us @3A
-1.3A/ us @1A (1 ohm & 2″ cable) |
RISE TIME
Rising Edge – Inductive (Varies with Load) | 4us (1 ohm, 50′ cable, 6A) |
Rising Edge – Resisitve (Varies with Load) | 550ns (1ohm, 2″ cable, 6A) |
Pulse Witdh Range | 5us – 100s* |
Error | +/-0.1% |
Resolution | 100 ns |
Delay Range | 0-1s |
Error | +/-0.1% |
Resolution | 100ns |
MONITOR OUTPUTS
Voltage Monitor (Isolated) | 1V/ V |
Current Monitor | 1V/A |
Error | < 4% |
Bandwidth | 150KHz |
RESISTANCE MEASUREMENT
Range | 0.1 to 150 Ohms |
Resolution | .01 Ohms |
Error .5 to 15 Ohms | < 4% |
Error 16 ro 150 Ohms | < 10 % |
Measurement Current | 100mA Max. |
SYNC OUTPUTS
Front and Rear |
---|
T0, Channels A through D |
SAFETY
Remote Interlock | Shorting interlock |
Arming Key Switch | Removable keyswitch |
COMMUNICATION
RS232 | 115200, 57600, 38400, 19200, 9600, 4800 baud |
USB | Serial Bridge |
Ethernet |
SIZE
Size |
---|
19″ 2Ux10″ Rack Mount |
ELECTRICAL
Electrical |
---|
100/240V, 50-60Hz |