PS1L420 – TETRA 420 – Tx 420 ~ 425 MHz, Tx 430 ~ 435 MHz
AWT’s PIM S1L TETRA and UHF analyzers are important for analyzing telecommunication infrastructure like antennas, cables and components. These very accurate PIM analyzers come with a wealth of standard features and measurement capabilities.
- Description
- Additional information
- Options & Accessories
- Specifications
Description
PS1L420 – TETRA 420 – Tx 420 ~ 425 MHz, Tx 430 ~ 435 MHz
Features
- Test Modes: Field Mode, Analyzer, multi PIM display, Rx sweep, PIM vs. Time, Single Carrier for Insertion Loss (IL) measurements.
- Embedded DTP option: Distance-to-PIM, VSWR, DTF
- High PIM sensitivity: -165 dBc @ 2x 43 dBm carriers.
- Data recording: CSV, PDF, BMP screen shots.
- Output power adjustable 2x 15dBm to 44dBm.
- Large 10.2″ Touch Screen Display.
- Convenient One-Body-Solution
Low PIM components and installations are particularly important for highest network capacity and reliable transmission. Signal degradation caused by PIM effects reduces data capacity and can lead to interrupted and even dropped calls.
S1L – MK2
PIM S1L TETRA & UHF analyzers ideal for component testing in laboratory and quality assurance, but are also valuable field tools, providing vital test results in TETRA & UHF networks. Specifications and measurement accuracy are exceptional and of PIM S1L analyzers deliver reliable results. They are very easy to operate; just the touch of a button to start predefined tests.
Our PIM S1L analyzers deliver constant CW Power signals during PIM measurements. This makes them fully conform to PIM specification IEC 62037, the standard for PIM testing. PIM S1L analyzers offer variable measurement signal output power from 15 dBm to 44 dBm. They provide even a Single-Carrier-Mode, ideal for Insertion Loss and coverage measurements.
Market leading dynamic range and low receiver noise level makes these analyzers perfect for testing, pinpointing and eliminating PIM. Results can be stored as PDF, BMP screen shots, or as CSV files. Our patented DTP measurement is highly accurate, and immediately available just at the push of a button.
“When public safety officers assign their staff to critical missions, they rely on the performance of their TETRA & UHF networks. Communication and data transmission must not experience any PIM distortion. PIM S1L MK2 TETRA & UHF helps to establish highest quality networks”.
Order Number |
Technologies / Type |
Tx Frequency (MHz) |
Rx Frequency (MHz) |
PS1L400 MK2 | TETRA | 390 ~ 400 | 380 ~ 385 |
PS1L400E MK2 | E-TETRA | 420 ~ 430 | 410 ~ 412 |
PS1L385 MK2 | TETRA 385 | 385 ~ 400 | 410 ~ 425 |
PS1L450 | LTE 450 Band 31 | 460 ~ 470 | 450 ~ 455 |
PS1L465 | LTE 450 MHz – UL / DL frequencies only | 462.5 ~ 467.5 | 452.5 ~ 457.5 |
Additional information
Weight | 28.5 kg |
---|---|
Dimensions | 50.4 × 39.8 × 27.6 cm |
POPT1 | DTP (Distance to PIM) / VSWR / DTF (Distance to Fault) Option | ||
PACC2 | Accessory Kit: (1) low PIM cable 3m / 10ft, low PIM load 50W / 10W ( 690-2800 MHz), (4) adapters, torque wrench with hard carry case | ||
PACC2L | Accessory Kit: (1) low PIM cable 3m / 10ft, low PIM 100W (380-2800 MHz), (4) adapters, torque wrench with hard carry case | ||
PIMGEN | PIM Source: Generator with preset PIM value of -80dBm (+/- 10). Quick indication of system functionality. Ideal for test and training. | ||
PLOAD100L | PIM Load 100W, PIM: < -163 dBc @ 2x43dBm, 380-28000 MHz, DIN 7/16(f) | ||
PLOAD50 | PIM Load: 50W / 10 W (30 mins / permanent), PIM: < -163 dBc @ 2x43dBm, 690-280 MHz, DIN7/16 (f) – DIN 7/16 (m) | ||
ADA-DMDF | Low PIM Adapter, PIM <-165dBc @ 2x43dBm, DIN(m)-DIN(f), Connector Saver | ||
LIC308-DMDM-2M | Low PIM Cable 2M (6ft), PIM<-165 dBc @ 2x43dBm, DIN(m) – DIN(m), metal protection collars | ||
LIC308-DMDM-1M | Low PIM Cable 1M (3ft), PIM<-165 dBc @ 2x43dBm, DIN(m) – DIN(m), metal protection collars |
Transmitter |
|
Carrier Power | +15 to +44 dBm |
Power Accuracy | +/- 0.35 dB |
Frequency Accuracy | 2 ppm |
Reverse Pwr. Protection | +43 dBm for 5 sec |
Receiver |
|
Reverse IM @ 2x43dBm | -122 dBm / -165 dBc typ. |
Noise Floor | -132 dBm (@300Hz) -126 dBm (1200 Hz) |
DynamicRange(typical) | > 96 dB (ref: -70 dBm) |
Reverse Power Protection | +43 dBm for 5 sec |
Operational Input Power | -45 dBm RMS |
Max Input Power | 0 dBm |
Measurement Accuracy | +/- 1.0 dB (typ) |
Distance to PIM / Distance to VSWR (Option) |
|
DTP Accuracy | 0.9 m typ. |
DTF Accuracy (VSWR) | 0.9 m |
Cable Types | Built-in list of cables Editing and adding new cable types (Attenuation, Velocity) |
Dimensions / Weight / Environment / Electrical |
|
Dimensions | 504 x 398 x 276 (mm) 19.8 x 15.7 x 10.9 (inch) |
Weight ( standard / with POPT1) | 28.5 kg (62.6 lb) / 30.5 kg (67.0 lb) |
Temperature | 0 °C to +40 °C |
Humidity | 85 %, RH (non condensing) |
Protection | IP20 |
AC Power | 100 to 240V 50/60 Hz |
Power Consumption | 700 Watts (VA) |