PS1L1800 – DCS/GSM1800 – Tx 1805 ~ 1880 MHz, Rx 1710 ~ 1785 MHz

Features

  • Test Modes: Diagnostic, Analyzer with Graphs, Sweep Mode (option), Distance to PIM (option), Distance to Fault (option).
  • Very high PIM sensitivity, up tp -172 dBc @ 2x 43 dBm carriers.
  • Output power variable from 15dBm to 44dBm.
  • Measures intermodulation products IM3, IM5 IM7, IM9, IM11 up to IM25
  • PIM over Time Graph and Sweep Mode
  • Maxhold feature
  • Data recording: CSV, PDF, Screenshot (BMP)

 

High quality, low PIM components are particularly important to achieve maximal network  capacity. Signal degradation affects operator’s revenue streams due to reduced data capacity. Leading global manufacturers use AWT Global PIM analyzers to guarantee lowest PIM values of of their wireless components and products.

Passive Intermodulation – PIM

Passive Intermodulation (PIM) is an unwanted mixing effect caused by non-linearity of passive components in the RF path of telecommunication systems. PIM diverts signal energy to other frequencies (spurious signals). This can generate interfering signals that may fall into receiving bands causing serious degradation of system performance.

Causes of PIM

  • Dissimilar metals with different electrical properties as well as corroded components and structures.
  • Ferromagnetic metals like iron, nickel and steel, show hysteresis effects when RF energy is applied.
  • Irregular contact areas, even on a microscopic scale, cause an inconsistent flow of electrons, generating inhomogeneous electrical fields.
  • Spark discharges that may happen by accidental “hot” connections and disconnections create craters on the connectors’ surfaces and lead to chemical reactions

Order Number

Technologies / Type

Tx Frequency (MHz)

Rx Frequency (MHz)

PS1L700ULTE700 / 700 MHz Upper Band730 ~ 759776 ~ 788
PS1L700LLTE700 / 700 MHz Lower band728 ~ 759698 ~ 716
PS1L700APTAPT700 / Asia Pacific Telecommunity / 3GPP-28758 ~ 803703 ~ 748
PS1L800LTE800791 ~ 821832 ~ 862
PS1L800SMRSMR800851 ~ 869806 ~ 824
PS1L850CDMA850 / 850 MHz869 ~ 896824 ~ 851
PS1L900GSM900 / 900 MHz935 ~ 960890 ~ 915
PS1L900EEGSM900925 ~ 960880 ~ 915
PS1L1500LTE-1500 Japan / 1500 MHz1488 ~ 15201456 ~ 1480
PS1L1800GSM 1800 / DCS 1800 / 1800 MHz1805 ~ 18801710 ~ 1785
PS1L1900PCS 1900 / 1900 MHz1930 ~ 19901850 ~ 1910
PS1L1921PAPCS 1900/ 1900 MHz
AWS / 2100 MHz
(Tx signal bands can be mixed)
1930 ~ 1935
2110 ~ 2155
1850 ~ 1910
1710 ~ 1755
PS1L2100AWSAWS2110 ~ 21551710 ~ 1755
PS1L2000TDTD-SCDMA(2000)2010 ~ 20251900 ~ 1920
PS1L2100UMTSUMTS/W-CDMA / 2100 MHz2110 ~ 21701920 ~ 1980
PS1L2160JPW-CDMA-JP2150 ~ 21702110 ~ 2140
PS1L2350WCSWireless Communication Services Band / WCS 2.3G2350 ~ 23602305 ~ 2315
PS1L2400LTELTE2400, Band 402300 ~ 23452355 ~ 2400
PS1L2500Band 41, BRS / EBS2593 ~ 26902496 ~ 2580
PS1L2600LTEIMT-E(2600) / LTE 2600 / 2600 MHz2620 ~ 26902500 ~ 2570
PS1L3500LTELTE2400, Band 423510 ~ 35903410 ~ 3490

Accessories

POPT1VSWR / DTP (Distance to PIM) Option
PACC2Accessory Kit: low PIM cables 3m / 10ft low PIM load 50W / 10W, adapters, torque wrench with hard carry case.
PLOAD100Low PIM Load: 100W, PIM <-165dBc @ 2x 43dBm, Frequency: 690 – 2800 MHz, Connector: DIN(f)
PLOAD50Low PIM Load: 50/10W, PIM <-165dBc @ 2x 43dBm, Frequency: 690 – 2800 MHz, 2 Connectors: DIN(f) – DIN(m)
ADA-DMDFConnector Saver. Adapter DIN(m)-DIN(f), PIM <-165dBc @ 2x43dBm, protects ports of PIM analyzers and loads.
LIC308-DMDM-1MLow PIM cable 1m (3ft), PIM <-165dBc @ 2x43dBm, DIN(m)-DIN(m), extra long metal sleeve for long lasting performance.
LIC308-DMDM-2MLow PIM cable 2m (6ft), PIM <-165dBc @ 2x43dBm, DIN(m)-DIN(m), extra long metal sleeve for long lasting performance.
PIMGENPIM Source: Passive generator with preset PIM value -80dBm (+/-10). Quick indication of system functionality. Ideal for test and training.

Additional information

Weight25.3 kg
Dimensions50.4 × 39.7 × 23.7 cm
POPT1VSWR / DTP (Distance to PIM) Option
PACC2Accessory Kit: low PIM cables 3m / 10ft low PIM load 50W / 10W, adapters, torque wrench with hard carry case.
PLOAD100Low PIM Load: 100W, PIM <-165dBc @ 2x 43dBm, Frequency: 690 – 2800 MHz, Connector: DIN(f)
PLOAD50Low PIM Load: 50/10W, PIM <-165dBc @ 2x 43dBm, Frequency: 690 – 2800 MHz, 2 Connectors: DIN(f) – DIN(m)
ADA-DMDFConnector Saver. Adapter DIN(m)-DIN(f), PIM <-165dBc @ 2x43dBm, protects ports of PIM analyzers and loads.
LIC308-DMDM-1MLow PIM cable 1m (3ft), PIM <-165dBc @ 2x43dBm, DIN(m)-DIN(m), extra long metal sleeve for long lasting performance.
LIC308-DMDM-2MLow PIM cable 2m (6ft), PIM <-165dBc @ 2x43dBm, DIN(m)-DIN(m), extra long metal sleeve for long lasting performance.
PIMGENPIM Source: Passive generator with preset PIM value -80dBm (+/-10). Quick indication of system functionality. Ideal for test and training.

Transmitter

Carrier Power+15 to +44 dBm (46 dBm optional)
Power Accuracy+/- 0.35 dB
Frequency Accuracy+/- 2 ppm
Reverse Pwr. Protection+43 dBm for 5 sec

Receiver

Reverse IM @ 2x43dBm ( all except 1921PA)
S1L 1921PA
S1L 2350 and higher frequencies
-129 dBm / -172 dBc typ.
-125 dBm / -168 dBc typ.
-122 dBm / -165 dBc typ.
Noise Floor
All analyzers except S1L1921PA
S1L1921PA
PSL2350 and higher frequencies
-138 dBm typ. @ 300 Hz BW
-132 dBm typ. @ 1200 Hz BW
-128dBm  typ. @ 1200 Hz BW (S1L1921PA )
-125dBm  typ. @ 1200 Hz BW (S1L2350 and higher frequencies)
Dynamic Range (typical)> 96 dB (ref: -70 dBm)
Reverse Power Protection+43 dBm for 5 sec
Operational Input Power-45 dBm RMS
Max Input Power0 dBm
Measurement Accuracy+/- 1.0 dB @ 2 x 43 dBm

Distance to PIM / Distance to VSWR (Option)

DTP Accuracy0.5 m typ.
DTF Accuracy (VSWR)0.5 m typ.
Cable TypesBuilt-in list of pre-defined cable types.
Adding and editing new cable types.

Dimensions / Weight / Environment / Electrical

Dimensions504 x 397 x 237 (mm)
19.8 x 15.6 x 9.3 (inch)
Weight25.3 kg (55.7 lb)
Temperature0 °C to +40 °C
Humidity85 %, RH (non condensing)
ProtectionIP20
AC Power100 to 240V 50/60 Hz
Power Consumption640 Watts (VA)

 