UT285C Three-Phase Power Quality Analyzer – For AI Data Center & GPU Rack Commissioning
-
-
-
-
UT285C Three Phase Power Quality Analyzer
- AI Rack & Facility Commissioning: Captures rapid voltage sags, swells, and 150 transient event records caused by high-density GPU cluster load swings.
-
4-Channel Real-Time Waveforms: Simultaneous 4U/4I measurement (up to 1000V phase-to-neutral / 2000V phase-to-phase, and up to 1000A–6000A depending on clamp selection).
-
Deep Harmonic & Transformer Diagnostics: Measures Total Harmonic Distortion (THD) up to the 50th order, Transformer K-Factor, three-phase unbalance, and short-term flicker (PST).
-
Long-Term Trend & Alarm Logging: Stores up to 12,800 alarm logs across 40 selectable parameters with USB/PC software for compliance reporting.
-
-
-
- Description
- Additional information
- SPECIFICATIONS
Description
AI Data Center & High-Density GPU Rack Applications
The UNI-T UT285C is a professional three-phase data center power analyzer engineered to verify electrical stability across high-density AI server racks, liquid-cooled GPU clusters, and enterprise power distribution networks. Modern AI training clusters generate rapid, multi-kilowatt load swings that place extreme stress on facility switchgear, uninterruptible power supplies (UPS), and step-down transformers. Using a dedicated data center power analyzer during facility commissioning and routine maintenance helps electrical engineers detect power anomalies before they cause costly server dropouts or breaker trips.
The UNI-T UT285C is a professional three-phase data center power analyzer engineered to verify electrical stability across high-density AI server racks, liquid-cooled GPU clusters, and enterprise power distribution networks. Modern AI training clusters generate rapid, multi-kilowatt load swings that place extreme stress on facility switchgear, uninterruptible power supplies (UPS), and step-down transformers. Using a dedicated data center power analyzer during facility commissioning and routine maintenance helps electrical engineers detect power anomalies before they cause costly server dropouts or breaker trips.
-
- Transient & Load Swing Capture: Logs up to 150 transient event records and captures high-speed voltage sags, swells, and peak current spikes caused by sudden GPU workload shifts.
- Harmonic Distortion & Transformer K-Factor: High-wattage AI server power supplies produce significant non-linear current harmonics. The UT285C analyzes harmonic distortion from order 1 to 50 and calculates Transformer K-Factor to help prevent neutral conductor overheating and transformer derating.
- Three-Phase Unbalance & Power Factor: Continuously monitors phase unbalance (0%–100%), Displacement Power Factor (DPF / cosφ), and active, reactive, and apparent power (kW, kVAR, kVA) to optimize PDU load balancing across server rows.
- Long-Term Compliance Logging: Records up to 12,800 alarm logs across 40 selectable electrical parameters and connects via USB to PC software for generating facility commissioning reports.
Key Technical Specifications for the UNI-T UT285C Data Center Power Analyzer
- Input Channels: 4 Voltage (4U) and 4 Current (4I) channels with automatic phasor diagram display
- Voltage Measurement Range: 1.0V to 1000V (Phase-to-Neutral) and 1.0V to 2000V (Phase-to-Phase)
- Current Measurement Range: 10mA to 1000A using standard 068B clamps, or up to 6000A with optional 300F flexible Rogowski coils
- Harmonics & Flicker Analysis: Orders 1–50, Total Harmonic Distortion (THD), Transformer K-Factor, and Short-Term Voltage Flicker (PST)
- Display & Memory: High-contrast color LCD waveform display with 150 transient records and 12,800 alarm logs
What’s Included with the UNI-T UT285C
- Analyzer & Power: UNI-T UT285C main unit, rechargeable lithium battery pack, and universal power adapter
- Probes & Clamps: 4 voltage test leads, 4 alligator clips, and 4 standard 1000A current clamps (UT-P068B)
- Accessories & Documentation: USB interface cable, PC analysis software, hard carrying case, and user manual
Additional information
| Weight | 1.6 kg |
|---|---|
| Dimensions | 240 × 170 × 68 cm |
Specifications of UT285C Three Phase Power Quality Analyzer
| Specifications | UT285C | |
| True RMS phase-to-neutral voltage | 1.0V~ 1000V | ±(0.5%+5dgt) |
| True RMS phase-to phase voltage | 1.0V~ 2000V | ±(0.5%+5dgt) |
| DC voltage | 1.0V~ 1000V | ±(1.0%+5dgt) |
| True RMS current | 008B current clamp: 10mA~10.0A(optional); 040B current clamp: 0.10A~100A(optional); 068B current clamp: 1.0A~1000A; 300F flexible current sensor (with Integrator) : 10A ~ 6000A(optional) |
±(0.5%+5dgt) |
| Peak of phase-to-neutral voltage | 1.0V~ 1414V | ±(1.0%+5dgt) |
| Peak of phase-to-phase voltage | 1.0V ~ 2828V | ±(1.0%+5dgt) |
| Current peak | 10mA ~ 6000A(optional) | ±(1.0%+5dgt) |
| Active power | 0.000W~ 9999.9kW | ±(1%+3dgt) |
| Cosφ≥0.8 | ||
| ±(1.5%+10dgt) | ||
| 0.2≤Cosφ<0.8 | ||
| Reactive power, inductive or capacitive | 0.000RVA~ 9999.9kVAR | ±(1%+3dgt) |
| Sinφ≥0.5 | ||
| ±(1.5%+10dgt) | ||
| 0.2≤Sinφ<0.5 | ||
| Apparent power | 0.000VA~ 9999.9kVA | ±(1%+3dgt) |
| Power factor | -1.000~ 1.000 | ±(1.5%+3dgt) |
| Cosφ≥0.5 | ||
| ±(1.5%+10dgt) | ||
| 0.2≤Cosφ<0.5 | ||
| Active energy | 0.000Wh~ 9999.9MWh | ±(1%+3dgt) |
| Cosφ≥0.8 | ||
| ±(1.5%+10dgt) | ||
| 0.2≤Cosφ<0.8 | ||
| Reactive energy, inductive or capacitive | 0.000VARh~ 9999.9MVARh | ±(1%+3dgt) |
| Sinφ≥0.5 | ||
| ±(1.5%+10dgt) | ||
| 0.2≤Sinφ<0.5 | ||
| Apparent energy | 0.000VAh~ 9999.9MVAh | ±(1%+3dgt) |
| Phase angle | -179°~ 180° | ±(2°) |
| Tanφ | -32.76~ 32.76 | φ:±(1°) |
| (VA>50VA) | ||
| Phase shift of power factor | -1.000~ 1.000 | φ:±(1°) |
| (DPF) | ||
| Harmonic ratio | 0.0%~ 99.9% | ±(1%+5dgt) |
| (order 1 to 50) (Vrms>50V) | ||
| Harmonic angle | -179°~ 180° | ±(3°) harmonics of order 1 to 25 |
| (Vrms>50V) | ±(10°) harmonics of order 26 to 50 | |
| Total harmonic ratio | 0.0%~ 99.9% | ±(1%+5dgt) |
| Distortion factor | 0.0%~ 99.9% | ±(1%+10dgt) |
| (DF or THD-R)<50 | ||
| Transformer K factor | 1.00~ 99.99 | ±(5%) |
| 3 phases unbalance | 0.0%~ 100% | ±(1%) |
| Number of channels | 4U/4I | |
| Parameters of electricity | W, VA, Var, PF, DPF, cosφ, tanφ | |
| Energy parameters | Wh, Varh, Vah | |
| Harmonic | 50 | |
| Total harmonic distortion | Order 0~50, each phase | |
| Expert mode | Yes | |
| Number of Transient records | 150 sets | |
| 3 phases unbalance | Yes | |
| Min/Max | Yes | |
| Alarm | 40 different types of parameter selections, 12,800 sets alarm logs | |
| Peak | Yes | |
| Phasor diagram display | Auto | |
| Auto power off | Yes | |
| Backlight | Yes | |
| Menu language | English/Chinese | |
| USB interface/PC software | Yes | |
| General Characteristics | ||
| Power | 9.6V rechargeable lithium-ion battery | |
| Product color | Red and grey | |
| Product net weight | Instrument: 1.6kg, current clamp: 510g x 4 | |
| Product size | 240mm × 170mm × 68 mm | |
| Standard accessories | 1pc carry cloth bag, (yellow, green, red, blue, black total 5pcs test lead), 4pcs alligator clip, 1pc power adapter, 4pcs 1000A current clamp | |
| Standard individual packing | Inner carton | |
| Standard quantity per carton | 1pc | |
| Standard carton measurement | 440 x 320 x 330mm | |
| Standard carton gross weight | 6.4kg | |