IT6333A Tripple Output DC power supply 60V/3A/180W*2CH; 5V/3A/15W*1CH
- Triple output voltage, all are adjustable.
- Optional serial/ parallel/ track mode*1
- The voltage and current for each channel can be displayed at the same time
- Small size of 1/2 2U
- VFD display
- Function keys with LED light
- Adjust the digital step value via cursor
- Output switch control
- High accuracy, high resolution and high stability
- Remote measurement function, compensation online pressure drop*2
- Comprehensive protection function
- Intelligent fan control, reduce noise
- Built-in RS232/USB/GPIB communication interface for part of the models
IT6300 Tripple Output DC power supply_Manual
- Description
- Additional information
- Options & Accessories
Description
IT6333A Tripple Output DC power supply 60V/3A/180W*2CH; 5V/3A/15W*1CH
IT6300 series is high-performance programmable triple channels DC power supply, each output voltage and current can be setfrom0 tomaximum rated output.This series provides series connection, parallelconnectionand synchronous functions ofchannel, which offer multi-purpose solutions forcustomerstest.IT6300 seriesis with high resolution1mV / 1mAand remote sense function, which make the test more accurate. Withbuilt-in standard USB / RS232 / GPIB communication interface,IT6300 seriesgreatly enhance the communication speed, and customersalsocanadjust the digital step value byusing the cursorto to facilitate the operation.
- Triple output voltage, all are adjustable.
- Optional serial/ parallel/ track mode*1
- The voltage and current for each channel can be displayed at the same time
- Small size of 1/2 2U
- VFD display
- Function keys with LED light
- Adjust the digital step value via cursor
- Output switch control
- High accuracy, high resolution and high stability
- Remote measurement function, compensation online pressure drop*2
- Comprehensive protection function
- Intelligent fan control, reduce noise
- Built-in RS232/USB/GPIB communication interface for part of the models
Functions and Advantages
Track mode
CH1 and CH2, CH2 and CH3, or all three channels to be set as track mode, if any one channel parameter changed, the corresponding parameters of the other channels will also change in direct proportion.
For example, set up voltage and current of CH1 and CH2 to be CH1:4V, 1A; CH2:8V, 2A. Set CH1 and CH2 in track mode, in output off and Meter state, VFD is shown below:
Additional information
Weight | 7.1 kg |
---|---|
Dimensions | 21.4 × 8.81 × 35.46 cm |
CD (accessory)
With user manual and communica…
|
AC power cord (accessory)
AC power cord (accessory)
|
IT-E123 (Optional)
RS485 optical isolation commun…
|
IT-E122 (Optional)
USB optical isolation communic…
|
IT-E121 (Optional)
RS232 optical isolation commun…
|
IT-E135 (Optional)
GPIB optical isolation communi…
|
IT-E151A (Optional)
19” Rack mount kit
|
IT-E151 (Optional)
19” Rack mount kit
|
IT-E30110-AB (Optional)
10A/1m/Alligator clip – Banana…
|
IT-E30110-BB (Optional)
10A/1m/Banana plug – Banana pl…
|
IT-E30110-BY (Optional)
10A/1m/Banana plug – Y termina…
|
USB
For USB port communication
|