4010 Precision Multi Product Calibrator (8ppm) + ISO 17025 accreditation

Calibrators supplied ready to use, including

  • ISO 17025 accreditation (Calibrator+ Options), Basic Test Lead Set, Localised mains lead
  • 1x USB Lead (main unit), 1x Serial COM Lead (Adapter Interface), Operation Manual.
  • 3 Year Warranty as standard

Calibrators & Options Supplied complete with ISO-17025 Accredited Certification

SKU: 4010 Category:
Brands:
Brands

Description

4010 Precision Multi Product Calibrator (8ppm)+ ISO 17025 accreditation

4010 ADVANCED MULTIPRODUCT CALIBRATOR

Calibrators supplied ready to use, including

  • ISO 17025 accreditation (Calibrator+ Options), Basic Test Lead Set, Localised mains lead
  • 1x USB Lead (main unit), 1x Serial COM Lead (Adapter Interface), Operation Manual.
  • 3 Year Warranty as standard

Calibrators & Options Supplied complete with ISO-17025 Accredited Certification

Key Features

  • 0 – 1000V DC / AC Voltage
  • 0 – 30A DC / AC Current
  • Variable Resistance up to 1GOhm
  • Variable Capacitance to 100mF
  • 1Hz – 10MHz Frequency
  • AC current maximum frequency 30kHz
  • Range of external accessories to increase workload
  • USB and GPIB interface fitted as standard
  • Removable Handles

 

Description

The 4000 Series is aimed at laboratories, manufacturers, and design facilities requiring a wide range of outputs with accuracies up to 8 ppm.

The 4000 Series builds on the trusted reliability of the 3000A Series, offering an updated user interface accessed through a large, 7″ touch screen to enable advanced functionality, including a built-in procedure mode and connection prompts, to minimize errors. USB printer capability supports production line automated test reporting without need for a PC and software

 

 

INNOVATIVE PROTECTION CIRCUITRY

The 4000 Series is protected by Transmille’s I-GUARD protection circuitry protecting the calibrator against accidental damage through wrong connections up to ± 1000V RMS.

All Transmille calibrators have been protected by I-GUARD since 2006

 

ILLUMINATED LOW THERMAL CONNECTION TERMINALS

Fitted with low thermal beryllium copper terminals, the 4000 Series enables connection with 4mm banana jacks, spades and bare wire without the need for additional adapters.

LED illumination identifies which terminals should be connected to depending on output settings of the calibrator

ADVANCED OSCILLOSCOPE CALIBRATION FUNCTIONALITY

Expanding the outputs offered by the 3000A Series, the 4000 Series provides an advanced oscilloscope calibration option with bandwidth calibration of up to 600 MHz with variable level. This expands the calibration workload to include spectrum analyzers and high bandwidth oscilloscopes.

Procedures can be loaded into the 4000 Series via USB memory stick, with results stored for integration back into ProCal software.

The 4000 Series also provides USB printer connectivity standard, supporting a wide range of PCL-compliant printers.

SOFTWARE COMPATIBILITY

As with all Transmille products, compatibility with ProCal calibration software is guaranteed. Existing procedures will not need to be re-written, due to Transmille’s unique implementation of flexible standards support where procedures are written around the UUT, not the standard.

 

Transmille 4000 Series Multi Product Calibrator

This video provides a brief overview of the 4000 Series Multi Product Calibrator.

4000 Series – Direct Ohms Selection

In this short video we demonstrate the latest updates to the 4000 series. The addition of new function keys enable direct access to the decade passive resistors enabling outputs to be directly accessed with a single touch of the screen.

4000 Series – Automated Verification

An example of the automated verification functionality using a Transmille 8081 precision multimeter.

4000 Series – Procedure Mode

Demonstration of the built-in procedure mode using a typical multimeter.

4000 Series – PWRDDS Video

Demonstration of the PWRDDS Option.

 

 

 

 

 

 

Additional information

Weight 20 kg
Dimensions 54.5 × 45 × 19 cm
ALL MODELS

CHOOSE THE PERFECT MODEL

4010 MODEL

4015 MODEL

DC Voltage
Best 1 Year Total Accuracy
0 – ±1025V
±8 ppm
0 – ±1025V
±15 ppm
DC Current
Best 1 Year Total Accuracy
0 – 30A
±50 ppm
0 – 30A
±50 ppm
AC Voltage
Best 1 Year Total Accuracy
20mV – 1000V, 10Hz – 1MHz
±0.015%
20mV – 1000V, 10Hz – 500kHz
±0.03%
AC Current
Best 1 Year Total Accuracy
20uA – 30A, 10Hz – 30kHz
±0.04%
20uA – 30A, 10Hz – 30kHz
±0.04%
Resistance (Passive)
Best 1 Year Total Accuracy
0 Ohms – 1 GOhm
±8 ppm
0 Ohms – 1 GOhm
±100 ppm
Resistance (Variable)
Best 1 Year Total Accuracy
0 Ohms – 1 GOhm
±100 ppm
0 Ohms – 1 GOhm
±100 ppm
Capacitance (Passive)
Best 1 Year Total Accuracy
1nF – 10uF
0.25%
1nF – 10uF
0.25%
Capacitance (Variable)
Best 1 Year Total Accuracy
0.95uF – 100mF
0.7%
0.95uF – 100mF
0.7%
Frequency
Best 1 Year Total Accuracy
10Hz – 1MHz
1 ppm
10Hz – 1MHz
20 ppm (1 ppm option)
Power
Best 1 Year Total Accuracy
DC/10Hz – 400Hz
0.06%/0.18%
DC/10Hz – 400Hz
0.08%/0.18%
Temperature (PRT/RTD)
Best 1 Year Total Accuracy
2 Wire Variable/2, 3, & 4 Wire Passive
±0.08°C/±0.02°C
2 Wire Variable/2, 3, & 4 Wire Passive
±0.08°C/±0.02°C
Temperature (Thermocouple)
Best 1 Year Total Accuracy
11 Types 11 Types
Inductance
Best 1 Year Total Accuracy
1mH – 10H
0.5%
1mH – 10H
0.5%

Internal Options (Choose At Time Of Order)

PRT/RTD Temperature Simulation (Option PRT, Included in -SYS Models)

The PRT option simplifies calibration of high-accuracy resistance thermometers. Reliable readings are guaranteed regardless of measurement technique, because the calibrator uses passive precision resistors.When the PRT option is calibrated, the precise temperature values on the ITS-90 scale for PT-385 resistors are stored in the memory.  The values can be recalled and displayed every time a specific resistor is chosen, to allow accurate calibration.

When combined with the SIMRC option, an additional 2-Wire variable output is available, which enables simulation of any value.

Simulated Resistance & Capacitance (Option SIMRC, Included in -SYS Models)

This option allows for resistance calibration between cardinal points. It has a continuous resistance range between 0 Ohms and 1 GOhms, with variable capacitance from 0.95uF to 100mF.

This option enables calibration of multimeters with non-decade calibration points.

Inductance Calibration Option (IND)

Simulated Resistance & Capacitance

This option allows for resistance calibration between cardinal points. It has a continuous resistance range between 0 Ohms and 1 GOhms, with variable capacitance from 0.95uF to 100mF.

This option enables calibration of multimeters with non-decade calibration points.

 

High Stability Frequency Output (Option FRQ, Included in 4010 models)

The FRQ option comes as standard on the 4010, and is an available option for the 4015.  It is a 1 ppm high-stability frequency output, for calibrating high accuracy frequency counters.

The FRQ option reduces equipment requirements for the calibration of hand-held frequency counters, and removes the need to install 10MHz distribution throughout the laboratory or workshop.

Oscilloscope Calibration (Option SCP)

Advanced oscilloscope calibration option, adding the ability to calibrate oscilloscopes to your multiproduct calibrator.

Waveforms for amplitude, timebase, rise time, and bandwidth are provided, with outputs up to 300V pk-pk.

SCP350 enables calibration of oscilloscopes up to 350 MHz.

SCP600 enables calibration of oscilloscopes up to 600 MHz.

(Option PWRSINE and PWRDDS)

The PWRSINE option enables cost-effective calibration of power (watts) and VA ranges on power meters and clamp meters with power measurement functions. The PWRSINE option provides variable voltage and current simultaneously, with an accurately adjustable phase relationship.

The PWRDDS option enables cost-effective calibration of power (watts) and VA ranges on power meters and clamp meters with power measurement functions. The PWRDDS option provides variable voltage and current simultaneously with an accurately adjustable phase relationship. In addition to the functions provided by PWRSINE, PWRDDS enables harmonics and distortion to be added to the power output for calibration of power quality functions of advanced power meters.

Pre-programmed harmonics are loaded into memory, with custom waveform shapes able to be loaded into the calibrator through the included computer software for completely customized testing with waveforms with custom harmonic content.

For both PWRSINE and PWRDDS:

Any voltage up to 1025V can be set, with a maximum current output of 30A without the need for external current amplifiers, allowing up to 1.5MW of power to be simulated.

The power function is very easy to use through intuitive menu design. Simply select ‘Power’ from the calibrator menu, enter the required parameters and connect the power meter to the indicated terminals. Voltage, current, frequency and phase can all be entered using the numerical keyboard, with phase angle adjustable to a resolution of 0.1°.

Power output is automatically calculated, and power factor and apparent power are also displayed on the screen automatically for quick comparison.

External Adaptors and Accessories (Add Anytime)

Thermocouple Simulation & Measurement Adapter (EA001A)

For the ultimate in accuracy, Transmille has designed a dedicated source/measure external adapter. This keeps the electronics required to generate the low-level signals used for thermocouple simulation as close as possible to the measuring input of the thermometer, which also allows the signal to be as free from electrical noise as possible, and eliminates errors caused by heat from surrounding electronics.

The cold junction compensation (CJC) sensor is mounted in the thermocouple plug itself. By measuring the cold junction at the instrument’s input, you can simulate any type of thermocouple without using thermocouple compensation cables.

Features

  • Enables fast and accurate calibration of thermocouple meters
  • Uses an innovative external measurement of cold junction temperature for ultimate accuracy
  • Utilizing a thermocouple plug removes the requirement for expensive thermocouple compensation cable

Option Documentation

EA001A Operation Manual
EA001A Extended Specifications
EA001A Calibration Guide

 

 

 

 

 

 

2/10/50 Turn Coil Adapter (EA002)

The Transmille EA002 offers several unique features.

Robust construction allows for years of hard use without risking damage to the coil.  An included alignment table ensures repeatable results.  This option was designed for the calibration of wound AC and magnetic field hall effect AC/DC clamp meters.

Features

Calibrates clamp meters up to 1500A (30A input)

Wide range of clamp sizes covered 2/10/50 Turn Coils

High accuracy AC/DC design, with minimal errors due to alignment

Alignment table included for accurate and repeatable readings

Option Documentation

EA002 Operation Manual

EA002 Extended Specifications
Understanding-Coil-Calibration-Uncertainties
EA002—Precision-Clamp-Coil-Adapter

 

 

Optical Tachometer Calibration Adapter (EA003)

Optical adapters can be calibrated quickly and easily, thanks to a high-intensity LED light source. Using the keypad, or ProCal software for automated calibration, simply enter the RPM value. With a range of 60 – 60,000 RPM, the EA003 can calibrate a whole range of optical tachometers.

Features

High-intensity LED light source Direct keyboard input in RPM

Control via ProCal for fully automated calibration

Output range from 60 to 60,000 RPM

Option Documentation

EA003 Operation Manual

EA003 Extended Specifications
EA003 Sample ISO-17025 Calibration Certificate

High Resistance/pA Measurement Adapter (EA008)

This option eliminates the need for a separate electrometer. The low-cost EA008 provides five current measurement ranges, down to 10nA, with a resolution of 1pA. It also incorporates a ‘virtual ground’ input, avoiding input impedance errors.

The EA008 allows high-accuracy resistance measurements at any voltage up to 1000V, with the high voltage output from the 4000 Series calibrators.

Features

  • Accurate current measurement down to 1pA resolution
  • Ideal for high value resistance measurements up to 1 TOhm
  • High resistance measurement voltages up to 1000V
  • 5 current measurement rnages from 10nA to 100uA
  • Control directly from the calibrator front panel or use with ProCal software

Option Documentation

EA008-Operation-Manual
EA008-Extended-Specifications

 

 

 

 

 

 

 

100A DC/70A AC Transconductance Amplifier (EA3012A)

The EA3012A is a powerful linear transconductance amplifier designed for use with Transmille calibrators to provide a cost-effective solution for generation of high currents.

The EA3012A connects directly to the adapter input connector on the front of Transmille calibrators and is controlled directly via the front panel with output in terms of Amps, or can be automated through ProCal calibration software.

Higher currents are available by paralleling multiple EA3012A amplifiers to reach currents in excess of 300A.

Features

100 DC/70A AC up to 400Hz Stackable for higher currents

Low-noise ultra linear MOSFET technology

Controlled directly via front panel of calibrator

Automation through ProCal software

Ideal for calibrating high current shunts, meters and clamp meters

Option Documentation

EA3012-Operation-Manual-V4-00-May-2018
EA3012A-Extended-Specifications

 

 

 

 

 

 

High Resistance/pA Measurement Adapter (EA013)

This option eliminates the need for a separate electrometer. The low-cost EA008 provides five current measurement ranges, down to 10nA, with a resolution of 1pA. It also incorporates a ‘virtual ground’ input, avoiding input impedance errors.

The EA008 allows high-accuracy resistance measurements at any voltage up to 1000V, with the high voltage output from the 4000 Series calibrators.

Features

Ideal for calibration of electrometer instruments

Source accurate current down to picoamp levels

Low open circuit compliance voltage

Safe to use on sensitive input circuits

Controlled directly from the calibrator front panel or via supplied software

Compatible with ProCal for full measurement automation

Option Documentation

EA013-Extended-Specifications
EA013—pA-Source-Adapter—Example-Certificate

Torque Calibration Adapter (EA014)

Connecting the EA014 to your Transmille calibrator adds torque calibration capabilities to your laboratory in a cost-effective way.

An external torque transducer allows you to calibrate torque screwdrivers up to 10Nm, with a range of torque transducers from 1Nm to 1500Nm.

Multi-Function Workstation (EA015)

The Multi-Function Workstation is a central work area, where all connections are conveniently routed to terminals mounted on the adapter front.

This workstation provides a versatile platform for efficient calibration of equipment, incorporating the advanced clamp coil, thermocouple simulation and tachometer calibration adapters.  It also includes process control source/measure capabilities.

Features

  • Insulation Testers
  • Continuity Testers
  • Optical Tachometers
  • Thermocouple Meters
  • Clamp Meters
  • Source functions of process control meters

Option Documentation

EA015-Operation-Manual-V1-10
EA015-Extended-Specifications
EA015—Workstation-Adapter—Example-Certificate

4-Channel Oscilloscope Test Head Adapter (EA017)

The EA017 provides a 4-channel switching test head for automation of oscilloscope calibration.

You can easily select a low impedance buffered amplitude output for accurate calibration of 50 Ohm output oscilloscopes.

Features

  • 4 Output channels for automating oscilloscope calibration
  • Minimizes lead changing when calibrating oscilloscopes
  • Choose between direct or buffered outputs for amplitude calibration

Option Documentation

EA017-Operation-Guide—web

 

 

 

 

3A/63V Power Supply Calibration Adapter (EA3023)

The EA3023 is an essential option for simplifying calibration of power supplies. The PSU adapter measures the output voltage, and provides a precision electronic load. This allows volts, current, and even output resistance to be calibrated in one compact unit. Accuracy and dependability are assured through 4-wire connection.

The output resistance of the PSU can be easily measured by measuring the on load/off load voltages of a power supply. Operation is controlled through the virtual front panel software (supplied) or ProCal.

Features

Measures voltage up to 63V Active current load to 3A

Calculates output resistance of a power supply for complete calibration

Option Documentation

EA3023-Operation-Manual-V1-00
EA3023-Extended-Specifications
EA3023—3A-63V-PSU-Adapter—Example-Certificate

AC/DC Kilovolt Amplifier (EA3024)

The EA3024, with its advanced electronics, is a simple and safe, cost-effective solution for calibration of high voltage probes and dividers.

It can be controlled through dedicated front panel software, or ProCal for safe calibration at high voltages.

Features

  • Outputs from 1kV to 10kV DC Outputs from 1kV to 5kV AC at up to 60Hz
  • Operated using supplied software or via ProCal calibration software

Option Documentation

EA3024-Operation-Manual-V1-00—WEB
EA3024-Extended-Specifications
EA3024–Example-Certificate

60A/60V Power Supply Calibration Adapter (EA3025A)

The EA3025A is an easy-to-use, low-cost solution for calibrating high current power supplies.

An accurate, stable electronic load simulates current load on power supplies, and allows measurement of voltage and output resistance.  It minimizes equipment required for calibrating these common devices.

Features

  • Easy to use, low cost solution. Accurate, stable electronic load
  • Minimizes equipment required for calibration

Option Documentation

EA3025A-Extended-Specifications

TPMXX Pressure Modules (TPM001 to TPM018)

A modern calibration laboratory must be able to perform calibration in multiple disciplines in order to remain competitive. Transmille has a range of pressure modules to assist, adding pressure management capability to our products.

Choose from a range of pressure modules that connect directly to our products, and provide read-back directly on-screen.

4000 Precision Lead Set (4000LEAD)

The 4000 Lead Set provides a comprehensive set of leads for making connections to typical test equipment. It comes in a hard carry case for safe transport and storage.

Transmille has undertaken careful consideration of leads and connection accessories to minimize errors and ensure safety. Non-retractable shrouds on voltage leads eliminate the risk of accidental shocks due to non-touch-proof leads.