UC8728C 8Ch OPTICAL MULTIPORT POWER METER

  • 4 channel and 8 channel optional
  • High dynamic range
  • High speed data acquisition and fast data transfer to computer
  • High channel test in one click
  • Save space and easy connet with computer with USB/RS232 cable
  • The order package with USB and RS232 communication cable, GUI software driver and user manual and programming  guide (almost same as Keysight N7745A).

pdf  31000040 UC8728 4-8 CH Power Meter Spec V200

pdf  31000041 UC872nC Multi Chanel Optical Power Meter User Manual V2.00

pdf 31000042 UC872nC Multi Chanel Optical Power Meter Programming Guide V2.00

SKU: UC8728C Category:
Brands

Description

UC8728C 8Ch OPTICAL MULTIPORT POWER METER

UC8728C 8Ch OPTICAL MULTIPORT POWER METER

UC INSTRUMENTS UC8728C 8 CHANNEL OPTICAL MULITIPORT POWER METER are PC control multiport passive components power meter test system and offer superior performance for the test of multi- channel DWDM, WSS, ROADM, AWG & PLC components and modules, optical amplifiers, DWDM system and other general purpose of multiport fiber optical test and measurement applications.  The system can be integrated with tunable laser source, optical attenuator & PDL controller provides a high performance passive components and modules automatic test system platform.

Features

  • 4 channel and 8 channel optional
  • High dynamic range
  • High speed data acquisition and fast data transfer to computer
  • High channel test in one click
  • Save space and easy connet with computer with USB/RS232 cable

Applications

  • Production PLC, AWG, WSS, ROADM multiport components and modules testing
  • Fiber Grating Sensor testing
  • PMD and PDL measurement
  • Fiber Optical , Telcom R & D lab test
  • It is easy to be integrated into a passive fiber components testing system

 

Additional information

Weight 4.5 kg
Dimensions 23.5 × 31 × 4.5 cm
Model # UC8724 UC8728
Channel Number 4 Channels 8 Channels
Wavelength Range 850 ~ 1700 nm
Power Range + 3 ~ -75 dBm
Application Fiber Type Standard SM and MM up to 62.5 um core size
Calibration Wavelength 850,980,1300, 1310,1490,1550,1625
Uncertainty (accuracy) at reference condition +/- 4% (1200 nm ~ 1610 nm)
Relative Uncertainty (accuracy) at

reference condition

< 0.04 dB Typical
Linearity (power) <= +/- 0.06 dB (1200 nm ~ 1610 nm, + 0~ -60 dBm)
Return Loss > 40 dB
Operation Temperature 0+40
Storage Temperature -30+80
Recalibration Period 2 years
Power Adaptor Power AC 100 – 240 V ±10%, 48 – 66 Hz, 100 VA max.
Display PC Interface.
Communication Port USB and RS232
Work Environmental −10°C to +70°C 0°C to +45°C

<95% R.H. from 0°C to +45°C

Dimensions 235mm W×45mm H×310mmD