4-Channel PXIe Precision Source Meter S0342C
4-channel high-precision PXIe source measure module, supports most of pxie chassis, It is convenient to integrate and extend to large integrated test system.
- Description
- Specifications
Description
4-Channel PXIe Precision Source Meter S0342C
Easy to expand
Single channel standard pxie precision power supply, easy to expand |
Large range
Range: ± 30 V, ± 500 MA (DC) |
High resolution
The minimum measurement resolution can reach 100pA/100uV |
High sampling rate
Up to 500K ADC sampling rate |
Functions and advantage
(5) function in one body Voltage source |
|
1、 Three quadrants as the source: the actual polarity of output V / I follows the source setting; 2、 The four quadrants are loads: CC and CV cooperate. When the load is used, the polarity of the load setting is opposite to the source polarity; |
|
Can test various equipment | |
Capture more measurement data ♦ 6-digit digital resolution: accuracy equivalent to 6-digit digital multimeter; |
|
Rich scanning function |
Voltage source index
Voltage setting accuracy | Range | Set resolution | Accuracy (1 year) ± (% reading + offset) | Typical noise (effective value)0.1 Hz-10Hz |
±30V | 500 uV | 0.03%+4 mV | 1000 μV | |
±6V | 100 uV | 0.03%+1 mV | 100 μV | |
Temperature coefficient | ±(0.15 × Accuracy)/°C (0℃-18℃,28℃-50℃) | |||
Channel 1 | CH0 reach CH3 | |||
Maximum output power of single channel | 3W: ±30V@0.1A,±6V@0.5A | |||
Set time | <200uS (Typical value) | |||
Overshoot | <±0.1% (Typical value, normal, step is 10% to 90% of the range, full scale point, resistive load test) | |||
Noise 10Hz-20MHz | 6V voltage source, 0.5A resistive load,<3mV RMS |
1,All channel outputs are electrically isolated from the earth, but all channel outputs are grounded(LO)
Current source index
Current setting accuracy | Range | Set resolution | Accuracy (1 year) ± (% reading + offset) | Typical noise (effective value)0.1 Hz-10Hz |
±500 mA1 | 10 uA | 0.05% + 100 μA | 10 uA | |
±100 mA | 2 uA | 0.05% + 10 μA | 1 uA | |
±10 mA | 200 nA | 0.05% + 5 μA | 100 nA | |
±1 mA | 20 nA | 0.05% + 500 nA | 10 nA | |
±100 μA | 2 nA | 0.05% + 50 nA | 1 nA | |
±10 μA | 200 pA | 0.05% + 20 nA | 150 pA | |
Temperature coefficient | ±(0.15 × Accuracy)/°C (0℃-18℃,28℃-50℃) | |||
Channel 2 | CH0 reach CH3 | |||
Maximum output power of single channel | 3W: ±30V@0.1A,±6V@0.5A | |||
Set time | <300us (Typical value) | |||
Overshoot | <±0.1% (Typical value, normal, step is 10% to 90% of the range, full scale point, resistive load test) |
1,500mA range only supports 6V voltage range
2,All channel outputs are electrically isolated from the earth, but all channel outputs are grounded(LO)
Voltmeter index
Voltmeter accuracy | Range | Measurement resolution | Accuracy (1 year) ± (% reading + offset) |
±30V | 1mV | 0.03%+4 mV | |
±6V | 100 uV | 0.03%+1 mV | |
Temperature coefficient | ±(0.15 × Accuracy)/°C (0℃-18℃,28℃-50℃) |
Ammeter index
Accuracy of ammeter | Range | Measurement resolution | Accuracy (1 year) ± (% reading + offset) |
±500 mA1 | 10 uA | 0.05% + 100 μA | |
±100 mA | 1 uA | 0.05% + 10 μA | |
±10 mA | 100 nA | 0.05% + 5 μA | |
±1 mA | 10 nA | 0.05% + 500 nA | |
±100 μA | 1nA | 0.05% + 50 nA | |
±10 μA | 100 pA | 0.05% + 20 nA | |
Temperature coefficient | ±(0.15 × Accuracy)/°C (0℃-18℃,28℃-50℃) |
1,500mA range only supports 6V voltage range
I-V output capacity
Output setup time
Output | Range | Typical output setup time | Test conditions: | ||
Fast1,2 | Normal1 | Slow1 | |||
Voltage source | 30V | <250μS | <780μS | <2.8ms | The time required to reach within 0.1% of the final value under open circuit load. In steps ranging from 10% to 90%. |
10V | <250μS | <780μS | <2.8ms | ||
Current source | ±500 mA | <50 μS | <330μS | <2.5ms | The time required to reach within 0.1% of the final value (0.3% for the 3 a range) under short circuit conditions. Steps are 10% to 90% of the range |
±100 mA | <50 μS | <270μS | <2.5ms | ||
±10 mA | <50 μS | <270μS | <2.5ms | ||
±1 mA | <50 μS | <290μS | <2.5ms | ||
±100 μA | <50 μS | <5mS | <2.5ms | ||
±10 μA | <150 μS | <3mS | <2.5m |
1,Output conversion rate:Fast,Normal,Slow。
2,The output of fast mode may have large overshoot under different ranges or load conditions. Slow mode is recommended for overshoot sensitive equipment.
Sampling rate and NPLC settings
Collocation method | Configuration scope |
NPLC | 0.0001PLC ~ 10PLC |
Sampling Rate | 5sps ~ 500Ksps |
Derating of measurement accuracy(PLC<1)
Error: percentage of range increase
PLC | Range | |||
6V 、30V | 10uA | 100uA to 100mA | 500mA | |
0.1 | 0.01% | 0.03% | 0.01% | 0.02 |
0.01 | 0.03% | 0.06% | 0.02% | 0.04% |
0.001 | 0.30% | 0.40% | 0.30% | 0.40% |
Supplementary features
Sensing mode | 2-wire or 4-wire (remote sensing) connection |
Maximum sensing lead resistance | 1 kΩ(accuracy rating) |
Maximum voltage between remote sensing output terminal and sensing terminal | 2V |
Maximum output voltage of output connector | >Full scale 105% |
DC floating ground voltage | ±60 V DC |
SWEEP scanning | The scanning interval is configurable from 20us to 16S, and the maximum scanning point is 64K |
Auto Range | Support. It is recommended to switch off the output before switching the range for overshoot sensitive equipment |
Delay measurement(SOURCE DELAY) | Support. It is recommended that the user set the appropriate source delay to obtain more accurate measurement values |
Over temperature protection | When the internal temperature is detected to be too high, the output will be turned off, and the operation will be resumed when the temperature returns below 65 ℃ |
Other output abnormal protection | Power off and restart to recover operation or hardware damage |
Environmental indicators
Environment | Use in indoor facilities |
Work | 0 ° C to + 50 ° C, 30% to 70% relative humidity non condensing |
Store | -30 ° C to 70 ° C, 10% to 90% relative humidity non condensing |
Altitude | Working height: 0 m to 2000 m, storage: 0 m to 4600 M |
Preheat | 1 hour |