3643N Millimeter-wave VNA extender 60 GHz 90 GHz
- Price for one set ( each set has 2 x 3643N) Frequency range: 60 GHz 90 GHz
- Frequency coverage: 40 GHz~500 GHz.
- Windows 7 operating system, Chinese menu, as well as English menu
- Various calibration methods such as frequency response, single port, response isolation, dual port, TRL and so
- Applicable to different types of vector network analyzer
- Realizing spread spectrum measurement of two-port vector network analyzer by 3640A. A uniform miniaturization and tilt panel design is adopted at different frequency Universal platform, easy to operate, and higher test efficiency.
- Description
- Additional information
- Specifications
- Ordering Information
Description
3643N Millimeter-wave VNA extender 60 GHz 90 GHz
- Price for one set ( each set has 2 x 3643N) Frequency range: 60 GHz 90 GHz
3643N Millimeter-wave VNA extender 60 GHz 90 GHz
3643K/43NA/43N/43P/43QA/43Q/49/43SA/43R/49A/49B
Millimeter-Wave VNA Extender
(40 GHz – 60 GHz/50 GHz – 75 GHz/60 GHz – 90 GHz/75 GHz – 110 GHz/90 GHz – 140 GHz/110 GHz – 170 GHz/170 GHz – 220 GHz/140 GHz – 220 GHz/170 GHz – 260 GHz/220 GHz – 325 GHz/325 GHz – 500 GHz)
Product Overview
The 3643K/43NA/43N/43P/43QA/43Q/49/43SA/43R/49A/49B Millimeter-Wave VNA Extender has reached the international level in measuring speed, dynamic range and measuring stability. In terms of hardware, this module adopts new design concepts and technical solutions, so that the key technical performance indicators of the whole unit are significantly improved; in terms of software, its spread spectrum system is based on the platform environment of Windows operating system, so that the inter-connectivity and usability of the whole unit has been greatly improved.
The 3643K/43NA/43N/43P/43QA/43Q/49/43SA/43R/49A/49B Millimeter-Wave VNA Extender can be used to compose a millimeter wave vector network analyzer system with a 3640A millimeter wave spread spectrum controller and a vector network analyzer, which can realize flexible configuration of 5 mm, 3 mm, 2 mm, 1 mm frequency band and an even higher frequency band, and the highest frequency can cover 500 GHz. It has the features of simple system configuration, friendly user interface and high test precision, and realizes the measurement of all S parameters of millimeter wave measured network. The system is widely used in R&D and production testing for millimeter wave components, MMIC, antenna and RCS and materials.
Main Features
- Frequency coverage: 40 GHz~500 GHz.
- Windows 7 operating system, Chinese menu, as well as English menu
- Various calibration methods such as frequency response, single port, response isolation, dual port, TRL and so
- Applicable to different types of vector network analyzer
- Realizing spread spectrum measurement of two-port vector network analyzer by 3640A. A uniform miniaturization and tilt panel design is adopted at different frequency Universal platform, easy to operate, and higher test efficiency.
Additional information
Dimensions | 240 × 120 × 90 cm |
---|
Model Technical Indicators | 3643K | 3643NA | 3643N | 3643P | 3643QA |
Frequency range | 40GHz~60GHz | 50GHz~75GHz | 60GHz~90GHz | 75GHz~110GHz | 90GHz~140GHz |
Port output power | ≥+6dBm | ≥+5dBm | ≥+5dBm | ≥5dBm | ≥+3dBm |
System dynamic range (intermediate frequency bandwidth 10 Hz) | ≥100dB | ≥100dB | ≥100dB | ≥100dB | ≥100dB |
Reflection tracking (dB) | ≤0.12 | ≤0.12 | ≤0.12 | ≤0.12 | ≤0.15 |
Transmission tracking (dB) | ≤0.12 | ≤0.12 | ≤0.12 | ≤0.12 | ≤0.15 |
Effective directivity (dB) | ≤-35dB | ≤-35dB | ≤-35dB | ≤-35dB | ≤-34dB |
Payload matching (dB) | ≤-35dB | ≤-35dB | ≤-35dB | ≤-35dB | ≤-34dB |
Port connector form | WR19, system Impedance 1 ohm | WR15, system Impedance 1 ohm | WR12, system Impedance 1 ohm | WR10, system Impedance 1 ohm | WR8.0, system Impedance 1 ohm |
Working voltage | 12VDC@2A | 12VDC@2A | 12VDC@2A | 12VDC@3A | 12VDC@3A |
Outline dimension width × height × depth (mm) | 120×90×240 | 120×90×240 | 120×90×240 | 120×90×240 | 120×90×240 |
3643Q | 3649 | 3643SA | 3643R | 3649A | 3649B |
110GHz~
170GHz |
170GHz~
220GHz |
140GHz~
220GHz |
170GHz~
260GHz |
220GHz~
325GHz |
325GHz~
500GHz |
≥-1dBm | ≥-10dBm | ≥-9dBm | ≥-10dBm | ≥-13dBm | ≥-23dBm |
≥100dB | ≥100dB | ≥100dB | ≥100dB | ≥95dB | ≥80dB |
≤0.15 | ≤0.2 | ≤0.25 | ≤0.2 | ≤0.2 | ≤0.3 |
≤0.15 | ≤0.2 | ≤0.25 | ≤0.2 | ≤0.2 | ≤0.3 |
≤-34dB | ≤-30dB | ≤-30dB | ≤-25dB | ≤-25dB | ≤-20dB |
≤-34dB | ≤-30dB | ≤-30dB | ≤-25dB | ≤-25dB | ≤-20dB |
WR6.5, system Impedance 1 ohm | WR5.1, system Impedance 1 ohm | WR5.1, system Impedance 1 ohm | WR4.3, system Impedance 1 ohm | WR3.4, system Impedance 1 ohm | WR2.2, system Impedance 1 ohm |
12VDC@2A | 12VDC@2A | 12VDC@2A | 12VDC@2A | 12VDC@3A | 12VDC@3A |
120×90×240 | 120×90×240 | 120×90×240 | 120×90×240 | 120×90×240 | 120×90×240 |
3640A millimeter wave spread spectrum controller, compatible with 3672X series and PNA-X series vector network analyzers.
Technical Specifications
Technical Indicators Model | Frequen cy range | Output power | Control interface | Power output | Power supply | Outline dimension width × height × depth (mm) |
3640A | 8G – 20GHz | 10±1dBm | Test device interface | 12VDC@2A | Self-adaption power supply: AC220/240V; 50/60Hz; 100/115V: 50/60/400Hz; | 426×177×460 (without handles, pad, feet) |
System Instrument List
Model | Instrument Name | Main Indicators | Quantity | Remarks |
3672B/C/D/E | Vector network analyzer | 10MHz~26.5GHz/40GHz
/50GHz/67GHz |
1 set | S80 option |
3640A | Millimeter wave spread spectrum controller | 8GHz~20GHz | 1 set | – |
3643K | Millimeter-wave VNA extender | 40GHz~60GHz | 2 sets | – |
3643NA | Millimeter-wave VNA extender | 50GHz~75GHz | 2 sets | – |
3643N | Millimeter-wave VNA extender | 60GHz~90GHz | 2 sets | – |
3643P | Millimeter-wave VNA extender | 75GHz~110GHz | 2 sets | – |
3643QA | Millimeter-wave VNA extender | 90GHz~140GHz | 2 sets | – |
3643Q | Millimeter-wave VNA extender | 110GHz~170GHz | 2 sets | – |
3649 | Millimeter-wave VNA extender | 170GHz~220GHz | 2 sets | – |
3643SA | Millimeter-wave VNA extender | 140GHz~220GHz | 2 sets | – |
3643R | Millimeter-wave VNA extender | 170GHz~260GHz | 2 sets | – |
3649A | Millimeter-wave VNA extender | 220GHz~325GHz | 2 sets | – |
3649B | Millimeter-wave VNA extender | 325GHz~500GHz | 2 sets | – |
32121K | 6mm waveguide calibration kit | 40GHz~60GHz | 1 box | – |
32156 | 5mm waveguide calibration kit | 50GHz~75GHz | 1 box | – |
32155N | 60-90 waveguide calibration kit | 60GHz~90GHz | 1 box | – |
32141 | 3mm waveguide calibration kit | 75GHz~110GHz | 1 box | – |
32155Q | 90-140 waveguide calibration kit | 90GHz~140GHz | 1 box | – |
32155 | 2mm waveguide calibration kit | 110GHz~170GHz | 1 box | – |
20301 | 1mm waveguide calibration kit | 140GHz~220GHz | 1 box | – |
32155S | 170-260 waveguide calibration kit | 170GHz~260GHz | 1 box | – |
20302 | 1mm waveguide calibration kit | 220GHz~325GHz | 1 box | – |
20301T | 0.5THz waveguide calibration kit | 325GHz~500GHz | 1 box | – |
– |
System connection cable |
– |
1 set |
See the following table for details |
Cable List of the Spread Spectrum System of the Controller
No. | Cable Name and Function | Length (meter) | Connector | Quantity | Remarks |
Microwave Cable | |||||
A1 |
RF output of network analyzer to RF input of control machine |
0.6 |
3.5mm/3.5mm-JJ |
1 |
Low loss cable |
A2 |
Local oscillator output of network analyzer to local oscillator input of control machine |
0.6 |
3.5mm/3.5mm-JJ |
1 |
Low loss cable |
A3/A4 |
RF output of control machine to input of millimeter-wave VNA extender. |
1.2/1.5/2 |
3.5mm/3.5mm-JJ |
2 |
Low loss cable, length optional |
A5/A6 |
Local oscillator output of control machine to local oscillator input of |
1.2/1.5/2 |
3.5mm/3.5mm-JJ |
2 |
Low loss cable, length |
millimeter-wave VNA extender. | optional | ||||
IF Cable | |||||
C1 |
IF output of control machine to outer IF input of control machine |
0.6 |
SMA/SMA |
4 |
IF cable |
C2 |
IF output of millimeter-wave VNA extender to IF input of control machine |
1.2/1.5/2 |
SMA/SMA |
4 |
IF cable, length optional |
Communication/Power Cable | |||||
D1 |
Interface of network analyzer test device to interface of control machine test device |
1 |
PCL-10125 |
1 |
Test device cable |
D2 |
Control machine power output to millimeter-wave VNA extender power input |
1.2/1.5/2 |
Circular connection cable |
2 |
Power cable, length optional |
Cable List of 3672B Vector Network Analyzer (Four-Port) Spread Spectrum System
No. | Cable Name and Function | Length (meter) | Connector | Quantity | Remarks |
Microwave Cable | |||||
A1 |
3672B complete machine four port spread spectrum system cable option |
/ |
/ |
1 |
RF cable kit |
Power Supply | |||||
C1/C2 |
Adapter power output to millimeter-wave VNA extender power input |
/ |
Seven core |
2 |
Power adapter |
Cable List of 3672C/D/E Vector Network Analyzer (Four-Port) Sprea Spectrum System
No. | Cable Name and Function | Length (meter) | Connector | Quantity | Remarks |
Microwave Cable | |||||
A1 |
3672C/D/E complete machine four port spread spectrum system cable option |
/ |
/ |
1 |
RF cable kit |
Power Supply | |||||
C1/C2 |
Adapter power output to millimeter-wave VNA extender power input |
/ |
Seven core |
2 |
Power adapter |