GTS-A6 Vector Signal Analyzer ,10 MHz to 6 GHz

Hot

GTS-A6 Vector Signal Analyzer ,10 MHz to 6 GHz

$5,450.00

  • Frequency range: 10MHz to 6000MHz
  • Signal demodulation: Digital signal, FM, and LTE
  • DANL: -166 dBm @1GHz (Sensitivity set to High, normalized to 1Hz)
  • Resolution bandwidth: 10Hz to 5MHz
  • Signal storage depth of 1Gbit for signal capture and analysis
  • API library is provided for secondary development

 

SKU: GTS-A6 Category:
Brands:
Brands

Options

+ $1,140.00
+ $1,910.00
+ $1,500.00
+ $1,500.00
+ $1,500.00
+ $1,500.00
Product price
Additional options total:
Order total:
  • Description
  • Additional information
  • Spesifications
  • Ordering List

Description

GTS-A6 Vector Signal Analyzer ,10 MHz to 6 GHz

GTS-A6 Main Functions

• General Spectrum Analysis

For conventional stable or periodic signals, the GTS-A6 provides broadband spectrum testing, including frequency and power measurements.

• Waterfall Display

GTS-A6 can display the frequency and amplitude change of the spectrum as a function of time in the form of waterfall display (Spectrogram), making the spectrum change at a glance.

• Digital Signal Demodulation

GTS-A6 supports ASK\PSK\FSK\QAM digital signal demodulation. Provide information such as spectrum, constellation, and EVM.

• LTE Signal Demodulation

GTS-A6 provides TDD-LTE and FDD-LTE downlink signal demodulation. Obtain spectrum records, time-frequency resource mapping, constellation, channel decoding, EVM, etc.

• NB-IoT Signal Demodulation

GTS-A6 provides air interface information demodulation for NBIoT. It can present multi-cell coverage and interference in the current wireless environment.

• FM Demodulation

GTS-A6 provides FM demodulation. The demodulated audio data can be stored in computer.

• Zero Span Mode

When analyzing the time domain characteristics of signal, user can set the span of instrument to 0 and enter zero span mode (like the oscilloscope). Video trigger can be used in this mode.

TYPICAL APPLICATION

• Laboratory RF test

GTS-A6 vector signal analyzer can perform RF testing in the laboratory. GTS-A6 combines GTS-G6 vector signal source can test intermodulation distortion of amplifiers, mixers, and receivers. This system can also test antennas, amplifiers, and attenuators’ performance such as bandwidth, frequency response, and gain.

• RF & Microwave Teaching Application

GTS-A6 vector signal analyzer, combine with GTS-G6 vector signal source, enables a demonstration of the testing of RF microwave devices. It reduces the complexity of RF microwave professional teaching and meets the teaching needs of telecom and electronic engineering related majors.

Compact Size & Fast Deployment

GTS-A6 is compact and easy to set up. User can easily carry to field and quickly build the test environment.

• System Integration & Secondary Development

GTS-A6 vector signal analyzer has a small size, superior specifications, comprehensive telecommunication & general demodulation support, and an open API interface. It also offers three different product models: full-size USB module, small-size USB module and PCB module. Thus, GTS-A6 can meet the system integration needs of different users.

Additional information

Weight1.8 kg
Dimensions18.0 × 29.0 × 5.0 cm
Function
SensitivityLow, Medium and High
DemodulatorDigital signals, FM, and LTE (AM, GSM, WCDMA, and NB-IoT will be supported in the future)
Frequency
Frequency Range10MHz to 6GHz
Frequenc ReferenceAging rate: ±1ppm
Frequency
Readout Accuracy
±( (readout frequency + 1GHz) x Frequency
Reference + Frequency Span Accuracy x Span)
Frequency Span Accuracy±1%
Sweep Time1.2ms to 1600s
2.69ms to 1600s, zero span
Resolution bandwidth
RBW Range10Hz to 5MHz, (1-2-3-5-10 Sequence)
RBW AccuracyRBW≥1MHz,±10%

RBW<1MHz, ±2%

Amplitude
Measuring RangeDisplay Average Noise Level to +20dBm
Input Attenuator Range0 to 30dB, 1dB Step
Maximum Safe Input LevelSensitivity: +30dBm (Low)
Sensitivity: 0dBm (Medium)
Sensitivity: -20dBm (High)
Reference Level Range-140 dBm to +20dBm
-190dBm to +70dBm (Ref level offset: ON)
Amplitude AccuracyATT set to 0dB, Input Signal: -5 to -30 dBm; Detector set to Positive; Sensitivity set to
Low; RBW Auto-Coupled, all other settings Auto-Coupled, 23±5℃
Half hour warm-up required.
±1.5dB
RBW Switching Uncertainty±0.3dB
Input Attenuator Uncertainty±0.6dB
Accuracy of Reference LevelReference level: ≥-60dBm, ±0.8dB
Display Average Noise Level (DANL) @1GHzInput
Terminated, Detector set to Positive, Trace Average set to 1000, Span set to
50kHz, Ref set to -100dBm, all other settings auto-coupled, 23±5 ℃.Normalized to 1 Hz RBW
Sensitivity: Low-129dBm/Hz (typically -131dBm/Hz)
Sensitivity: Medium-148dBm/Hz (typically -150dBm/Hz)
Sensitivity: High-166dBm/Hz (typically -168dBm/Hz)
Residual Response-75dBm(-65dBm@1161MHz-1181MHz/5760-5766MHz)
Input-Related Response10MHz to 1.1GHz<-70dBc
1.1GHz to 1.85GHz, 2.9GHz to 2.97GHz<-41dBc
1.85GHz to 2.9GHz, 2.97GHz to 3.11GHz, 3.7GHz to 5.6GHz<-50dBc
3.11GHz to 3.70G, 5.8GHz to 5.9G<-39dBc
5.9GHz to 6.0GHz<-30dBc
Second Harmonic Distortion1.6GHz to 70dBc
Third-Order Intercept (TOI)-10dBm tones, 1MHz apart, Sensitivity set to low, Ref set to -10 dBm

+15dBm

P1dB+5dBm (nominal)
Phase Noise @1GHz-95dBc/Hz, @10kHz (typically -98dBc/Hz)
-115dBc/Hz, @1MHz (typically -120dBc/Hz)
Storage
Maximum storage depth1Gbit
Data formatI/Q two-way, 16bit
Bandwidth2.5Mz, 5MHz, 10MHz, 20MHz
Sampling rate30.72MHz, 15.36MHz, 7.68MHz, and 3.84MHz
General
OS for SoftwareWindows7,  Windows 10
Power Supply Current2A Max
TemperatureOperating: 0°C to 50°C

Storage: -20°C to 70°C

Connect interfaceRF output: N-type, 50 Ω
PC connect:USB type-C
Power connect: DC12V
Dimension and Weight180mm×50mm×290mm, 1.8kg

Technical specifications

This technical specifications include the influence of probability distribution, measurement uncertainty and environmental factors on the instrument performance. It guarantees the performance under the following conditions.

  • The instrument is ON and warmed up for 30 min
  • The instrument internal reference signal is applied

Testing temperature is 23±5 ºC, unless other specific condition applied.

Typical value

Additional description does not cover all performance information of the product guarantee. Unless otherwise specified, the typical value refers to the indicator or technical specification with which more than 80% of products comply under 23 ± 5 ºC. The measurement uncertainty is excluded. GTS-A6 should be within the calibration period.

Nominal value

The nominal value refers to the characteristic description or design range. It is not tested or covered by the product. GTS-A6 should be within the calibration period.

Model

Description

GTS-A6

GTS-A6 Vector Signal Analyzer (10MHz to 6000MHz)

Accessories Model

Description

GTS-MRX-AS001

Power adapter

GTS-MRX-AS002-I

Power cable (China standard)

GTS-MRX-AS002-B

Power cable (US standard)

GTS-MRX-AS002-G

Power cable (UK standard)

GTS-MRX-AS002-F

Power cable (US standard)

GTS-MRX-AS004

USB cable

GTS-MRX-AS004

USB disk

GTS-MRX-S003

Spectrum analysis and playback software

GTS-MRX-S004

Waterfall display and FM demodulaiton

Options

GTS-MRX-S001

NB-IoT demodulation license

GTS-MRX-S002

IQ signal capture license

GTS-MRX-S005

TD-LTE demodulation licence

GTS-MRX-S008

FDD-LTE demodulation license

GTS-MRX-S006

Digital demodulation license

GTS-MRX-S007

10MHz Ref IN/OUT Option

GTS-MRX-AS006

Universal power adapter

error: Alert: Content is protected !!