  • Frequency Range:1Mz to 6.5GHz
  • Dynamic Range:>117 dB (IFBW=10 Hz), 121dB typical
  • Low Noise Level:<-120 dBm (IFBW=10 Hz)
  • Low Trace Noise:10 mdB rms (IFBW=3 kHz)
  • High Measurement Speed:120 μs/point (IFBW=30 kHz)
  • High Effective Directivity:>42 dB
  • Remote Control:LabView
  • Low Power Consumption:18W

    T-Series-USB-Vector-Network-Analyzer-Datasheet

SKU: GTS-T6 Category:
Brands:
Brands

Options

High Precision, DC to 9GHz, 50Ω, N-type Calibration Kit Set

High Precision, DC to 6.5GHz, 50Ω, N-type Calibration kit Set, case included

High Precision, DC to 9GHz, 50Ω, SMA-type Calibration Kit Set

High Precision, DC to 6.5GHz, 50Ω, SMA-type Calibration kit Set, case included

Product price
Additional options total:
Order total:
View cart

Description

GTS-T6 USB VECTOR NETWORK ANALYZER

GTS-T6 USB Vector Network Analyzer offers wide dynamic range, low noise level, high resolution scanning with laboratory and research grade performance. GTS-T6 covers frequency range of 1MHz to 6.5GHz, with 2-port and 2-pass that competitive with most of the bench-top VNAs on the market. The T6 USB VNA provides measurement convenience by offering end user excellent performance and attractive pricing. T6 USB VNA is suitable for laboratory, manufacturing and many other safety testing environment.

KEY FACTS

  • Frequency Range:1Mz to 6.5GHz
  • Dynamic Range:>117 dB (IFBW=10 Hz), 121dB typical
  • Low Noise Level:<-120 dBm (IFBW=10 Hz)
  • Low Trace Noise:10 mdB rms (IFBW=3 kHz)
  • High Measurement Speed:120 μs/point (IFBW=30 kHz)
  • High Effective Directivity:>42 dB
  • Remote Control:LabView
  • Low Power Consumption:18W

FEATURES

  • Capable of replacing bench-top VNA
  • Minimum budget requirement
  • Suitable for laboratory, manufacturing and research and development purposes
  • Compact design, implementation simplicity and various system upgrade

 

 

Additional information

Weight 2.3 kg
Dimensions 18 × 5 × 29 cm
Testing Range Description
Impedance 50Ω
Test Port Connector N-type, female
Number of Test Port 2
Frequency Range 1MHz to 6.5GHz
Low Noise Level < -120dBm (IFBW=10 Hz)
Frequency Accuracy 5ppm
Frequency Resolution 10Hz
Number of Measurement Points 2 to 10001
Measurement Bandwidths 1Hz to 50kHz
Dynamic range (IFBW 10Hz) 117dB, typ.121 dB
Measurement parameters S11, S21, S12, S22
Testing Accuracy
Transmission Measurement Accuracy (magnitude/phase)
+5 dB to +10 dB 0.2dB/2º
-50 dB to +5 dB 0.1dB/1º
-70dB to -50dB 0.5 dB/3º
-90dB to -70dB 2.5 dB/8º
Reflection Measurement Accuracy(magnitude/phase)
-15dB to 0dB 0.4dB/3º
-25dB to -15dB 1.0dB/6º
-35dB to -25dB 3.0dB/20º
Trace stability
Trace noise magnitude (IF bandwidth 3kHz) 10 mdB rms
Temperature Dependence (per one degree of temperature variation) 0.02dB
Effective System Data①
Effective Directivity 42 dB
Effective Source Match 40 dB
Effective Load Match 42 dB

①Applied over them temperature range of 23°C ± 5°C after 40 minutes of warming-up, with less than 1°deviation from the full two-port calibration temperature, at output power of -5dBm and IF bandwidth 10Hz.

 

Test port output Description
Match(W/O system error correction) 18 dB
Power Range -50 dBm to +5 dBm
Power Accuracy ±1.5 dB
Power Resolution 0.05dB
Test port input
Match(W/O system error correction) 18 dB
Max Input Level +23 dBm
Max Input Voltage +35 V
Noise level(IF Bandwidth 10Hz) -115 dBm
General Data
External Reference Input SMA female; 10 MHz; 2 dBm ± 3 dB
External Reference Output SMA female; 10 MHz; 3 dBm ± 2 dB
Operating Temperature Range +5°C to +40°C
Storage Temperature Range -45°C to +55°C
Operating Humidity 90% (25°C)
Operating Atmospheric Pressure 84 to 106.7 kPa
Calibration Interval 3 years
Power Supply 110/220 ± 22 V (AC), 50 Hz
Power Consumption 18W
Dimensions(W x H x D) mm 180x50x290
Weight 2.3kg
Comparision between VNA modules
  Transcom

T6

Tektronix

TTR500

Copper Mountain

S5048

Frequency Range 1MHz to 6.5GHz 100kHz to 3GHz

100kHz to 6GHz

20kHz to 4.8GHz
Dynamic Range(IFBW 10 Hz) 117dB 122dB 120dB
Trace Noise (dBrms) 0.01 0.008 0.002
Output Power -30/-50 to +5 dBm -50 to +7 dBm -50 to +5 dBm
Measurements S11,S12,S21,S22 S11,S12,S21,S22 S11,S12,S21,S22
Frequency Resolution 10Hz 1Hz 10Hz
Frequency Accuracy ±5ppm ±7ppm ±5ppm