AV3672D VNA 10MHz~50GHz

Hot

AV3672D VNA 10MHz~50GHz

$78,788.00

AV3672 series vector network analyzer provides multiple calibration types including frequency response, single port, response isolation, enhanced response and full dual-port, electronic calibration etc.; It offers various display formats such as logarithmic amplitude, linear amplitude, standing-wave, phase, group delay, Smith chart and polar coordinates, etc.;

SKU: AV3672D Category: Tag:
Brands:
Brands
Product price
Additional options total:
Order total:
  • Description
  • Additional information
  • Technical Specifications:
  • Ordering Information:

Description

AV3672D VNA 10MHz~50GHz

AV3672 series vector network analyzer is consist of AV3672A (10MHz~13.5GHz), AV3672B  (10MHz~26.5GHz), AV3672C   (10MHz~40GHz), AV3672D VNA  (10MHz~50GHz)  and AV3672E (10MHz ~ 67GHz). In terms of hardware, comparing to last generation, the brand-new design concept and technical proposal have upgraded key performance indexes (KPI) of the complete machine  such  as  sweep  speed  and  dynamic  range  etc.;  in  terms  of  software,   the  embedded computer system (ECS) with high-performance microprocessor chip and the platform based on Windows operating system have greatly improved interconnectivity and usability of the complete machine. AV3672 series vector network analyzer provides multiple calibration types including frequency response, single port, response isolation, enhanced response and full dual-port,  electronic calibration etc.; It offers various display formats such as logarithmic amplitude, linear amplitude, standing-wave, phase, group delay, Smith chart and polar coordinates, etc.; It is designed with several standard interfaces: USB, LAN, GPIB and VGA etc. Besides all measurement functions same as traditional vector network analyzer, through configuration of functional options, AV3672 series vector network analyzer is also capable of multifunctional & comprehensive parameter test of mixer/converter, gain compression two-dimensional sweep and pulse  S-parameters,  as  well  as  accuracy  measurement  of  amplitude-frequency  characteristics, phase-frequency characteristics and group delay characteristics of microwave network. AV3672 series Vector Network Analyzer can be widely used in the field of transmitting/receiving (T/R) module measurement, dielectric material properties measurement, microwave pulse characteristics measurement and optoelectronic properties measurement, which is an indispensable instrument for scientific research and manufacturing process of radar, communication, and navigation systems.

Main Features:

  • Flexible and optional calibration types, compatible with multiple calibration kits
  • Support multi-window, multi-channel tests, fast implementation of complex test scheme
  • Available in multiple display formats such as logarithmic amplitude, linear amplitude, standing-wave, phase, Smith chart
  • With USB, GPIB, LAN and VGA display interface
  • Chinese/English operation interface, 12.1-inch high resolution touch screen
  • Record/run, one-button operation greatly simplifies the measurement setting steps and improves the efficiency
  • Available in functions as pulse S parameter measurement, time-domain measurement, mixer measurement, gain compression two-dimensional sweep measurement, millimeter-wave frequency extension, antenna & RCS measurement and receiving etc.

 

Additional information

Weight47 kg
Dimensions69.0 × 46.3 × 28.1 cm

AV3672A/B Technical Specifications

Frequency characteristic
Frequency range10MHz~13.5/26.5GHz
Frequency resolution1Hz
Frequency accuracy±1×10-7 (23℃±3℃)
Port harmonic suppression
Harmonic suppression  on  port 1 and 3-48dBc (0.01~4GHz)-57dBc (4~26.5GHz)
Harmonic suppression  on  port 2 and 4-13dBc (0.01~4GHz)-18dBc (4~26.5GHz)
Port power characteristic
  

Power sweep range

33dB (10~50MHz)30dB (0.05~4GHz)

34dB (4~7GHz)

31dB(7~13.5GHz)

29dB (13.5~20GHz)

25dB (20~26.5GHz)

  

 

Max. output power

(standard configuration, option 400)

 Frequency rangeFiltering mode of port 1 and 3High power mode of port 1 and 3 Port 2 and 4
10~50MHz0dBm+9dBm+13dBm
0.05~4GHz0dBm+6dBm+13dBm
4~7GHz+12dBm+10dBm
7~13.5GHz+8dBm+9dBm
13.5~20GHz+6dBm+6dBm
20~26.5GHz+4dBm+2dBm
  

 

 

Max. output power (option 201, 401, 402)

 Frequency rangeFiltering mode of port 1 and 3High power mode of port 1 and 3 Port 2 and 4
10~50MHz-1dBm+9dBm+12dBm
0.05~4GHz-1dBm+6dBm+12dBm
4~7GHz+10dBm+9dBm
7~13.5GHz+6dBm+8dBm
13.5~20GHz+4dBm+5dBm
20~26.5GHz+2dBm+0dBm
Power linearity (23℃±3℃)±2.0dB
Pulse characteristic
Pulse transition time(10%-90%)30ns
Pulse on/off   ratio64dB (0.01~4GHz)80dB (4~26.5GHz)
Network parameter characteristic
  

System dynamic range

90dB (0.01~1GHz)120dB (1~4GHz)

127dB (4~10GHz)

120dB (10~20GHz)

115dB (20~24GHz)

110dB (24~26.5GHz)

 

Effective directivity48dB (0.01~2GHz)44dB (2~26.5GHz)
Effective source match40dB (0.01~2GHz)30dB (2~26.5GHz)
Effective load match48dB (0.01~2GHz)44dB (2~26.5GHz)
Reflection tracking±0.04dB (0.01~2GHz)±0.05dB (2~26.5GHz)
Transmission tracking±0.10dB (0.01~2GHz)±0.12dB (2~26.5GHz)
Others
 Amplitude trace noise

dB rms(1kHz IF bandwidth)

0.050 (10~50MHz)0.007 (50~500MHz)

0.002 (0.5~13.5GHz)

0.003 (13.5~20GHz)

0.005 (20~26.5GHz)

 Phase trace noise

deg rms(1kHz IF bandwidth)

0.200 (10~50MHz)0.051 (50~500MHz)

0.042 (0.5~13.5GHz)

0.054 (13.5~20GHz)

0.054 (20~26.5GHz)

IF bandwidth1Hz~5MHz
Amplitude display resolution0.001dB/div
Phase display resolution0.01°/div
Setting requirement of reference level amplitude-500~+500dB
Setting requirement of reference level phase-500~+500°
General characteristic
Port connectors3.5mm (male), 50 ohm system impedance
Number of measuring portsAV3672A/B standard configuration:2 ports;AV3672A/B-400 option:4 ports
Peripheral interfaceUSB, GPIB, VGA, LAN
Operating systemWindows 7
Display12.1-inch high resolution touch screen
 DimensionsW´H´D=426mm×266mm×550mm (excluding bottom foot and handle)W´H´D=463mm×281mm×640mm (including handle, bottom foot and back foot)
Max. power consumption400W
Max. weight42kg

 

AV3672C/D Technical Specifications

Frequency characteristic
Frequency range10MHz~43.5/50GHz
Frequency resolution1Hz
Frequency accuracy±1×10-7 (23℃±3℃)
Port harmonic suppression
Harmonic suppression on port 1 and 3-48dBc (0.01~4GHz)-57dBc (4~13.5GHz)

-57dBc (13.5~50GHz)

Harmonic suppression on port 2 and 4-13dBc (0.01~4GHz)-18dBc (4~13.5GHz)

-57dBc (13.5~50GHz)

Port power characteristic
  

Power sweep range

32dB (10MHz~50MHz)29dB (0.05~4GHz)

28dB (4~13.5GHz)

30dB (13.5~40GHz)

27dB (40~47GHz)

15dB (47~50GHz)

  

 

Max. output power (standard configuration, option

400)

 Frequency rangeFilteringmode of port 1 and 3High powermode of port 1 and 3 Port 2 and 4
10~50MHz-1dBm+8dBm+11dBm
0.05~4GHz0dBm+5dBm+9dBm
4~13.5GHz+5dBm+6dBm
13.5~40GHz+7dBm+7dBm
40~47GHz+5dBm+5dBm
47~50GHz-7dBm-7dBm
  

 

 

Max. output power (option 201, 401, 402)

 Frequency rangeFiltering mode of port 1 and 3High power mode of port 1 and 3 Port 2 and 4
10~50MHz-2dBm+7dBm+10dBm
0.05~4GHz-1dBm+4dBm+8dBm
4~13.5GHz+3dBm+4dBm
13.5~40GHz+5dBm+5dBm
40~47GHz+2dBm+2dBm
47~50GHz-10dBm-10dBm
Pulse characteristic
Pulse transition time (10%-90%)30ns
Pulse on/off   ratio64dB (0.01~4GHz)80dB (4~50GHz)
Network parameter characteristic
  

System dynamic range

74dB (0.01~1GHz)119dB (1~13.5GHz)

115dB (13.5~26.5GHz)

110dB (26.5~35GHz)

105dB (35~47GHz)

90dB (47~50GHz)

Effective directivity42dB (0.01~13.5GHz)

 

38dB (13.5~40GHz)36dB (40~50GHz)
 Effective source match36dB (0.01~2GHz)31dB (2~13.5GHz)

28dB (13.5~40GHz)

27dB (40~50GHz)

 Effective load match42dB (0.01~13.5GHz)37dB (13.5~40GHz)

35dB (40~50GHz)

 Reflection tracking±0.04dB (0.01~13.5GHz)±0.03dB (13.5~40GHz)

±0.04dB (40~50GHz)

 Transmission tracking±0.1dB (0.01~13.5GHz)±0.16dB (13.5~40GHz)

±0.20dB (40~50GHz)

Others
  

Amplitude trace noise

dB rms(1kHz IF bandwidth)

0.050 (10~50MHz)0.020 (50~500MHz)

0.005 (0.5~13.5GHz)

0.004 (13.5~26.5GHz)

0.005 (26.5~40GHz)

0.008 (40~50GHz)

 Phase trace noise

deg    rms (1kHz IF bandwidth)

0.900 (10~50MHz)0.700 (50~500MHz)

0.040 (0.5~13.5GHz)

0.050 (13.5~26.5GHz)

0.060 (26.5~50GHz)

IF bandwidth1Hz~5MHz
Amplitude display resolution0.001dB/div
Phase display resolution0.01°/div
Setting requirement of reference level amplitude-500~+500dB
Setting requirement of reference level phase-500~+500°
General characteristic
Port connectors2.4mm (male), 50 ohm system impedance
Number of measuring portAV3672C/D standard configuration:2 ports, AV3672C/D-400 option: 4 ports
Peripheral interfaceUSB, GPIB, VGA, LAN
Operating systemWindows 7
Display12.1-inch high resolution touch screen
 DimensionsW´H´D=426mm×266mm×600mm (excluding bottom foot and handle)W´H´D=463mm×281mm×690mm (including handle, bottom foot and back foot)
Max. power consumption500W
Max. weight47kg

 

AV3672E Technical Specifications

Frequency characteristics
Frequency range10MHz~67GHz
Frequency resolution1Hz
Frequency accuracy±1×10-7 (23℃±3℃)
Port harmonic suppression
Harmonic suppression on port 1 and 3-48dBc (0.01~4GHz) typical value: -51dB (0.01~4GHz)-57dBc (4~67GHz) typical value: -60dBc (4~67GHz)
Harmonic suppression on port 2 and 4-13dBc (0.01~4GHz)-18dBc (4~13.5GHz) typical value: -21dBc (4~13.5GHz)

-57dBc (13.5~67GHz) typical value: -60dBc (13.5~67GHz)

Port power characteristics
  

Power sweep range

32dB (10~50MHz)29dB (0.05~4GHz)

28dB (4~26.5GHz)

29dB (26.5~35GHz)

26dB (35~40GHz)

25dB (40~67GHz)

  

 

Max. output power

(standard                        configuration, option 400)

Frequency rangeFiltering modeof port 1 and 3High power modeof port 1 and 3Port 2 and 4
10~50MHz-1dBm+8dBm+8dBm
0.05~4GHz0dBm+5dBm+5dBm
4~26.5GHz+5dBm+5dBm
26.5~35GHz+7dBm+7dBm
35~40GHz+4dBm+4dBm
40~67GHz+5dBm+5dBm
  

 

Max. output power (option 201, 401, 402)

Frequency rangeFiltering mode of port 1 and 3High power mode of port 1 and 3Port 2 and 4
10~50MHz-2dBm+7dBm+7dBm
0.05~4GHz-1dBm+4dBm+4dBm
4~26.5GHz+3dBm+3dBm
26.5~35GHz+4dBm+4dBm
35~40GHz+1dBm+1dBm
40~67GHz0dBm0dBm
Pulse characteristics
Pulse        transition        time (10%-90%)30ns
Pulse on/off   ratio64dB (0.01~4GHz)80dB (4~67GHz)
Network parameter characteristic
  

 

System dynamic range

74dB (0.01~1GHz)90dB (1~4GHz)

107dB (4~10GHz)

110dB (10~26.5GHz)

100dB (26.5~35GHz)

90dB (35~50GHz)

75dB (50~67GHz)

Effective directivity35dB (0.01~2GHz)41dB (2~13.5GHz)

 

34dB (13.5~40GHz)32dB (40~67GHz)
 Effective source match35dB (0.01~2GHz)31dB (2~13.5GHz)

28dB (13.5~40GHz)

25dB (40~67GHz)

 Effective load match35dB (0.01~2GHz)41dB (2~13.5GHz)

33dB (13.5~40GHz)

30dB (40~67GHz)

 Reflection tracking±0.05dB (0.01~2GHz)±0.06dB (2~13.5GHz)

±0.08dB (13.5~40GHz)

±0.10dB (40~67GHz)

 Transmission tracking±0.10dB (0.01~2GHz)±0.11dB (2~13.5GHz)

±0.16dB (13.5~40GHz)

±0.20dB (40~67GHz)

Others
 Amplitude trace noise

dB rms(1kHz IF bandwidth)

0.050 (10~50MHz)0.020 (50~500MHz)

0.005 (0.5~13.5GHz)

0.004 (13.5~26.5GHz)

0.020 (26.5~67GHz)

 Phase trace noise

deg rms(1kHz IF bandwidth)

0.90 (10~50MHz)0.70 (50~500MHz)

0.04 (0.5~13.5GHz)

0.05 (13.5~26.5GHz)

0.10 (26.5~67GHz)

IF bandwidth1Hz~5MHz
Amplitude display resolution0.001dB/div
Phase display resolution0.01°/div
Setting       requirement       of reference level amplitude-500~+500dB
Setting       requirement       of reference level phase-500~+500°
General characteristics
Port connectors1.85mm (male), 50 ohm system impedance
Number of measuring portsAV3672E standard configuration:2 ports, AV3672E-400 option: 4 ports
Peripheral interfaceUSB, GPIB, VGA, LAN
Operating systemWindows 7
Display12.1-inch high resolution touch screen
 DimensionsW´H´D=426mm×266mm×600mm (excluding bottom foot and handle)W ´ H ´ D=463mm×281mm×690mm (including handle, bottom foot and back foot)
Max. power consumption500W
Max. weight50 kg

 

 

Main unit                           Description
AV3672AVector network analyzer (10MHz ~ 13.5GHz)
AV3672BVector network analyzer (10MHz ~ 26.5GHz)
AV3672CVector network analyzer (10MHz ~ 43.5GHz)
AV3672DVector network analyzer (10MHz ~ 50GHz)
AV3672EVector network analyzer (10MHz ~ 67GHz)

 

Standard configuration:

No.                     DescriptionRemarks
1Power cord assembly                                   Standard three-core power cord
2USB keyboard/mouse
3User manual
4Certificate of conformity
5Aluminum alloy box

 

AV3672A options

ModelDescriptionRemarks
 

AV3672A-201

2-port      programmable       step attenuatorSet two 70dB programmable step attenuators for the source path, and two 35dB  programmable step attenuators for the receiver path
AV3672A-4004-port measurementTwo-source       stimulus configurationfour-portVNA
 

AV3672A-401

 

4-port      programmable       step attenuator

Set four 70dB programmable step attenuators for the source path, and four 35dB programmable step attenuators for the receiver path (option 400 is needed)
AV3672A-402Active                         intermodulation measurementFor intermodulation signal measurement of amplifier (option 400 is needed)
AV3672A-008Pulse measurementFor pulse S-parameter measurement
 

AV3672A-S10

 

Time domain measurement

For time-domain test, can locate and analyze the discontinuous  positions  in  devices,  fixtures  or

cables.

 

AV3672A-S80

 

Frequency offset measurement

For        frequency        offset        measurement.

Millimeter-wave frequency extension main unit needs this option

AV3672A-S82Mixer scalar measurementFor  the  scalar parameter measurement  of mixers

(option 400 is needed)

AV3672A-S83Mixer vector measurementFor the vector parameter measurement of mixers (option 400 is needed)
AV3672A-S84Embedded       LO       frequency converter measurementFor the measurement of embedded LO frequency converters(option 400 is needed)
AV3672A-S86Gain compression two-dimension sweep measurementFor the gain compression two-dimension sweep test of amplifier
AV311213.5mm calibration kitFor calibration of the analyzer
FB0HA0HB025.03.5mm testing cableFor measurement of the analyzer
FB0HA0HC025.03.5mm testing cableFor measurement of the analyzer
AV20403E-cal moduleFor        calibration        of (10MHz-26.5GHz, 2 ports)theanalyzer
AV20405E-cal moduleFor calibration of  the analyzer (10MHz-20GHz, 4 ports)

 

AV3672B options

ModelDescriptionRemarks
 

AV3672B-201

2-port      programmable       step attenuatorSet two 70dB programmable step attenuators for the   source  path,   and  two  35dB programmable

step attenuators for the receiver path

AV3672B-4004-port measurementTwo-source       stimulus configurationfour-portVNA
 

AV3672B-401

 

4-port      programmable       step attenuator

Set four 70dB programmable step attenuators for the source path, and four 35dB programmable step attenuators for the receiver  path (option 400

is needed)

AV3672B-402Active                intermodulation

measurement

For    intermodulation    signal    measurement  of

amplifier (option 400 is needed)

AV3672B-008Pulse measurementFor pulse S-parameter measurement
 

AV3672B-S10

 

Time domain measurement

For time-domain test, can locate and analyze the discontinuous positions in devices, fixtures or cables.
 

AV3672B-S80

 

Frequency offset measurement

For frequency offset measurement. Millimeter-wave frequency extension main unit needs this option
AV3672B-S82Mixer scalar measurementFor the scalar parameter measurement of mixers (option 400 is needed)
AV3672B-S83Mixer vector measurementFor the vector parameter measurement of mixers (option 400 is needed)
AV3672B-S84Embedded       LO       frequency converter measurementFor the measurement of embedded LO frequency converters(option 400 is needed)
AV3672B-S86Gain compression two-dimension

sweep measurement

For the gain  compression  two-dimension  sweep

test of amplifier

AV311213.5mm calibration kitFor calibration of the analyzer
FB0HA0HB025.03.5mm testing cableFor measurement of the analyzer
FB0HA0HC025.03.5mm testing cableFor measurement of the analyzer
AV20403E-cal moduleFor        calibration        of

(10MHz-26.5GHz, 2 ports)

theanalyzer
AV20405E-cal moduleFor calibration of the  analyzer  (10MHz-20GHz, 4 ports)

AV3672C options:

ModelDescriptionRemarks
 

AV3672C-201

2-port      programmable       step attenuatorSet two 60dB programmable step attenuators for the  source  path,  and  two  35dB  programmable

step attenuators for the receiver path

AV3672C-4004-port measurementTwo-source configurationstimulusfour-portVNA
 

AV3672C-401

 

4-port      programmable       step attenuator

Set four 60dB programmable step attenuators for the source path, and four 35dB  programmable step attenuators for the receiver path  (option 400

is needed)

AV3672C-402Active                intermodulation

measurement

For    intermodulation    signal    measurement  of

amplifier (option 400 is needed)

AV3672C-008Pulse measurementFor pulse S-parameter measurement
 

AV3672C-S10

 

Time domain measurement

For time-domain test, can locate and analyze the discontinuous positions in devices, fixtures or cables.
 

AV3672C-S80

 

Frequency offset measurement

For frequency offset measurement. Millimeter-wave frequency extension main unit needs this option
AV3672C-S82Mixer scalar measurementFor the scalar parameter measurement of mixers (option 400 is needed)
AV3672C-S83Mixer vector measurementFor the vector parameter measurement of mixers (option 400 is needed)
AV3672C-S84Embedded       LO       frequency converter measurementFor the measurement of embedded LO frequency converters(option 400 is needed)
AV3672C-S86Gain compression two-dimension

sweep measurement

For  the  gain  compression two-dimension sweep

test of amplifier

AV311232.4mm calibration kitFor calibration of the analyzer
FE0BN0BM025.02.4mm testing cableFor measurement of the analyzer
FE0BN0BL025.02.4mm testing cableFor measurement of the analyzer
AV20404E-cal moduleFor calibration of the analyzer (45MHz-40GHz 2

ports)

AV3672D options

ModelDescriptionRemarks
 

AV3672D-201

2-port       programmable       step attenuatorSet two 60dB programmable step attenuators for the source path, and two 35dB programmable step attenuators for the receiver path
AV3672D-4004-port measurementTwo-source configurationstimulusfour-portVNA
 

AV3672D-401

 

4-port       programmable       step attenuator

Set four 60dB programmable step attenuators for the source path, and four 35dB programmable step attenuators for the  receiver path (option 400

is needed)

AV3672D-402Active                          intermodulation measurementFor intermodulation signal measurement of amplifier (option 400 is needed)
AV3672D-008Pulse measurementFor pulse S-parameter measurement
 

AV3672D-S10

 

Time domain measurement

For time-domain test,  can locate and analyze the

discontinuous positions in devices, fixtures or cables.

 

AV3672D-S80

 

Frequency offset measurement

For frequency offset measurement. Millimeter-wave frequency extension main unit needs this option
AV3672D-S82Mixer scalar measurementFor the  scalar parameter measurement  of mixers

 

(option 400 is needed)
AV3672D-S83Mixer vector measurementFor the vector parameter measurement of mixers (option 400 is needed)
AV3672D-S84Embedded       LO       frequency converter measurementFor the measurement of embedded LO frequency converters(option 400 is needed)
AV3672D-S86Gain compression two-dimension sweep measurementFor the gain compression two-dimension sweep test of amplifier
AV31123A2.4mm calibration kitFor calibration of the analyzer
FE0BN0BM025.02.4mm testing cableFor measurement of the analyzer
FE0BN0BL025.02.4mm testing cableFor measurement of the analyzer

AV3672E options:

ModelDescriptionRemarks
 

AV3672E-201

2-port     programmable      step attenuatorSet two 50dB programmable step attenuators for the source path, and two 50dB programmable step

attenuators for the receiver path

AV3672E-4004-port measurementTwo-source stimulus four-port VNA configuration
 

AV3672E-401

 

4-port     programmable      step attenuator

Set four 50dB programmable step attenuators for the source path, and four  50dB  programmable step attenuators for the receiver path (option 400

is needed)

AV3672E-402Active                       intermodulation measurementFor   intermodulation    signal    measurement    of amplifier (option 400 is needed)
AV3672E-008Pulse measurementFor pulse S-parameter measurement
 

AV3672E-S10

 

Time-domain measurement

For time-domain test, can locate and analyze the

discontinuous positions in devices, fixtures or cables.

 

AV3672E-S80

 

Frequency offset measurement

For frequency offset measurement. Millimeter-wave frequency extension main unit needs this option
AV3672E-S82Mixer scalar measurementFor    the    scalar    parameter    measurement    of mixers(option 400 is needed)
AV3672E-S83Mixer vector measurementFor    the    vector    parameter    measurement    of

mixers(option 400 is needed)

AV3672E-S84Embedded      LO      frequency converter measurementFor the measurement of embedded LO frequency converters(option 400 is needed)
 

AV3672E-S86

Gain                     compression two-dimension                sweep measurementFor the gain compression two-dimension sweep test of amplifier
AV311281.85mm calibration kitFor calibration of the analyzer
FF0CN0CM025.0

FF0CN0CL025.0

1.85mm testing cableFor measurement of the analyzer

 

error: Alert: Content is protected !!