3672E Vector Network Analyzer (10MHZ ~ 67GHZ)

Hot

3672E Vector Network Analyzer (10MHZ ~ 67GHZ)

$109,091.00

  • Simple control method: one LAN line, one GPIB card
  • Effectively lower the test cost, liberate limited human resources
  • Finish more tests in effective time, greatly shorten the development period
  • Finish the task impossible for manpower, such as accurate timing, tests under complex environment
SKU: 3672E Category:
Brands:
Brands
Product price
Additional options total:
Order total:

Description

3672E Vector Network Analyzer (10MHZ ~ 67GHZ)

3672E Vector Network Analyzer (10MHZ ~ 67GHZ)

3672A/B/C/D/E Vector Network Analyzer (10 MHz ~ 67 GHz)

Product Overview

3672 Series Vector Network Analyzers include 3672 A (10 MHz~13.5 GHz), 3672B (10 MHz~26.5 GHz), 3672 C (10 MHz~43.5 GHz), 3672D (10 MHz~50 GHz) and 3672E (10 MHz~67 GHz). In terms of hardware, comparing to last generation, the brand-new design concept and technical proposal have upgraded key performance indexes (KPI) of the complete machine such as sweep speed and dynamic range etc.; in terms of software, the embedded computer system (ECS) with high-performance microprocessor chip and the platform based on Windows operating system has greatly improved inter-connectivity and usability of the complete machine. 3672 analyzers provide multiple calibration types including frequency response, single port, response isolation, enhanced response and full dual-port, electronic calibration etc., offer various display formats such as logarithmic amplitude, linear amplitude, standing-wave, phase, group delay, Smith chart and polar coordinates, etc.

They are designed with several standard interfaces: USB, LAN, GPIB and VGA etc. Besides all measurement functions same as traditional vector network analyzer, through configuration of functional options, 3672 analyzers are also capable of multi-functional & comprehensive parameter test of mixer/converter, gain compression two-dimensional sweep and pulse S-parameters, as well as accuracy measurement of amplitude-frequency characteristics, phase-frequency characteristics and group delay used in the field of transmitting/receiving (T/R) module measurement, dielectric material properties measurement, microwave pulse characteristics measurement and optoelectronic properties measurement, which are indispensable instruments for scientific research and manufacturing process of radar, communication, and navigation systems.

Main Characteristics

  • Flexible and optional calibration types, compatible with multiple calibration kits
  • Support multi-window, multi-channel tests, fast implementation of complex test scheme
  • Available in multiple display formats such as logarithmic amplitude, linear amplitude, standing-wave, phase, Smith chart
  • With USB, GPIB, LAN and VGA display interface
  • 1 inch high resolution touch screen
  • Record/run, one-click operation greatly simplifies the measurement setting steps and improves the efficiency
  • Available in functions as pulse S parameter measurement, time-domain measurement, mixer measurement, gain compression two-dimensional sweep measurement, millimeter-wave frequency extension, antenna & RCS measurement and receiving .

Humanized user interface for easy operation, which can improve the efficiency

Parameters can be quickly input through activated input toolbar.

It can improve the test efficiency to setup the limit line and segment sweep value for production line.

The soft panel can be put on left or right side of the screen. Or it can be hidden for operation convenience.

Flexible and optional calibration types, compatible with multiple calibration kits

3672 Series of Vector Network Analyzers provide multiple calibration types, including guided calibration (automatic calibration), unguided calibration (using mechanical calibration kit to conduct through response calibration, through response & isolation calibration, single port calibration, enhanced response calibration, full two-port SOLT calibration, TRL calibration) and electronic calibration (E-Cal) etc.. Users can select calibration kits, such as coaxial 3.5 mm calibration kit and electronic calibration kit based on test requirements, which greatly facilitates testing on devices with different interfaces.

Multiple windows to display all measuring channels

The analyzers possess functions of multi-channel and multi-window display, support up to 64 channels. Maximum 16 measuring windows can be simultaneously displayed, and each window can simultaneously display up to 8 test traces, which makes the observation results more visible and the operation more convenient.

Rich peripheral interfaces, flexible and practical 

Adopting the software & hardware platform consisting of embedded computer module compatible with PC and Windows operation system, 3672 Series of Vector Network Analyzers realize the perfect combination of the instrument and PC. Users can use the rich I/O interfaces (including GPIB, USB, and LAN etc.) to complete the optimum selection of data communication.

Low trace noise, high test accuracy

Time-domain analysis can comprehensively characterize the design

With time-domain options, 3672 Series of Vector Network Analyzers can realize the switching of measurement results between frequency-domain and time-domain, which can be used to identify the discontinuous points of devices, fixtures or cables to realize accurate fault location.

Automatic test

Calibration is complicated: short-circuiter, open-circuiter, load, through – SO PROFESSIONAL! Set up the same parameters over and over again – VERY BORING!

Products need to be tested under harsh conditions – BUT PEOPLE NEEDN’T!

Setting changing and data recording need to be done at set intervals – UNFORTUNATELY,I AM NOT A TIMER!

3672 Series of Vector Network Analyzers can provide you integrated automatic test solutions including automatic calibration, automatic measurement, automatic reading and automatic printing.

Flexible and multiple control modes are provided through GPIB, LAN, and USB interfaces. All you need to do is to finish the interconnection of equipment and send the command.

What benefits does automatic test bring for you?

  • Simple control method: one LAN line, one GPIB card
  • Effectively lower the test cost, liberate limited human resources
  • Finish more tests in effective time, greatly shorten the development period
  • Finish the task impossible for manpower, such as accurate timing, tests under complex environment

 

 

 

Additional information

Weight 47 kg
Dimensions 51.6 × 64.0 × 28.0 cm

3672A/B Technical Specifications

Frequency Characteristic
Frequency Range 10MHz~13.5/26.5GHz
Frequency Resolution 1Hz
Frequency

Accuracy

±1×10-7(23℃±3℃)
Port Harmonic Suppression Typical Value
Harmonic Suppression on Port 1 And 3 -48dBc(0.01~4GHz)

-57dBc(4~13.5GHz)

-57dBc(13.5~26.5GHz)

-51dBc(0.01~4GHz)

-60dBc(4~13.5GHz)

-60dBc(13.5~26.5GHz)

Harmonic Suppression On Port 2 And 4 -13dBc(0.01~4GHz)

-18dBc(4~13.5GHz)

-18dBc(13.5~26.5GHz)

-13dBc(0.01~4GHz)

-21dBc(4~13.5GHz)

-21dBc(13.5~26.5GHz)

Port Power Characteristic Typical Value
 

 

Power      Sweep Range

33dB(10~500MHz)

30dB(0.5~4GHz)

34dB(4~7GHz)

31dB(7~13.5GHz)

29dB(13.5~20GHz)

25dB(20~26.5GHz)

42dB(10~500MHz)

37dB(0.5~4GHz)

42dB(4~7GHz)

41dB(7~13.5GHz)

38dB(13.5~20GHz)

35dB(20~26.5GHz)

 

 

 

 

Max. Output Power (Standard Configura tion, Option 400)

 

 

 

 

Port 1, 3

0dBm(0.01~4GHz)(Filter Mode)

+9dBm(10~50MHz)(High Power Mode)

+6dBm(0.05~4GHz)(High Power Mode)

+12dBm(4~7GHz)

+8dBm(7~13.5GHz)

+6dBm(13.5~20GHz)

+4dBm(20~26.5GHz)

+16dBm(10~50MHz)(High Power Mode)

+11dBm(0.05~4GHz)(High Power Mode)

+16dBm(4~7GHz)

+14dBm(7~13.5GHz)

+11dBm(13.5~20GHz)

+9dBm(20~26.5GHz)

 

 

Port 2, 4

+13dBm(10~50MHz)

+13dBm(0.05~4GHz)

+10dBm(4~7GHz)

+9dBm(7~13.5GHz)

+6dBm(13.5~20GHz)

+2dBm(20~26.5GHz)

+16dBm(10~50MHz)

+16dBm(0.05~4GHz)

+16dBm(4~7GHz)

+15dBm(7~13.5GHz)

+13dBm(13.5~20GHz)

+8dBm(20~26.5GHz)

 

 

 

Max. Output Power (Option 201, 401,

402)

 

 

 

 

Port 1, 3

-1dBm(0.01~4GHz)(Filter Mode)

+8dBm(10~50MHz)(High Power Mode)

+5dBm(0.05~4GHz)(High Power Mode)

+10dBm(4~7GHz)

+6dBm(7~13.5GHz)

+4dBm(13.5~20GHz)

+2dBm(20~26.5GHz)

+15dBm(10~50MHz)(High Power Mode)

+10dBm(0.05~4GHz)(High Power Mode)

+15dBm(4~7GHz)

+13dBm(7~13.5GHz)

+10dBm(13.5~20GHz)

+8dBm(20~26.5GHz)

Port 2, 4 +12dBm(10~50MHz)

+12dBm(0.05~4GHz)

+15dBm(10~50MHz)

+15dBm(0.05~4GHz)

+9dBm(4~7GHz)

+8dBm(7~13.5GHz)

+5dBm(13.5~20GHz) 0dBm(20~26.5GHz)

+15dBm(4~7GHz)

+14dBm(7~13.5GHz)

+12dBm(13.5~20GHz)

+7dBm(20~26.5GHz)

1dB

Compression Level

 

/

 

+13dBm

Pulse Characteristic Typical Value
Pulse               Width Setting Range 33ns~60s 20ns~60s
Pulse Transition Time

(10%-90%)

 

30ns

 

20ns

Pulse              On/Off Ratio 64dB(0.01~4GHz)

80dB(4~26.5GHz)

Network Parameter Characteristic Typical Value
 

 

System Dynamic Range

90dB(0.01~1GHz)

120dB(1~4GHz)

127dB(4~10GHz)

120dB(10~20GHz)

115dB(20~24GHz)

110dB(24~26.5GHz)

100dB(0.01~1GHz)

128dB(1~4GHz)

135dB(4~10GHz)

132dB(10~20GHz)

129dB(20~24GHz)

125dB(24~26.5GHz)

Effective Directivity 48dB(0.01~2GHz)

44dB(2~26.5GHz)

60dB(0.01~2GHz)

53dB(2~26.5GHz)

Effective Source Match 40dB(0.01~2GHz)

30dB(2~26.5GHz)

46dB(0.01~2GHz)

36dB(2~26.5GHz)

Effective   Load Match 48dB(0.01~2GHz)

44dB(2~26.5GHz)

60dB(0.01~2GHz)

51dB(2~26.5GHz)

Reflection Tracking ±0.04dB(0.01~2GHz)

±0.05dB(2~26.5GHz)

±0.004dB(0.01~2GHz)

±0.010dB(2~26.5GHz)

Transmission Tracking ±0.10dB(0.01~2GHz)

±0.12dB(2~26.5GHz)

±0.005dB(0.01~2GHz)

±0.015dB(2~26.5GHz)

Others Typical Value
Amplitude Trace Noise

dB rms(1kHz If Bandwidth)

0.0500(10~50MHz)

0.0070(50~500MHz)

0.0020(0.5~13.5GHz)

0.0030(13.5~20GHz)

0.0050(20~26.5GHz)

0.0020(10~50MHz)

0.0008(50~500MHz)

0.0009(0.05~13.5GHz)

0.0008(13.5~20GHz)

0.0010(20~26.5GHz)

Phase        Trace Noise

deg rms(1kHz IF    Bandwidth)

0.200(10~50MHz)

0.051(50~500MHz)

0.042(0.5~13.5GHz)

0.054(13.5~20GHz)

0.054(20~26.5GHz)

0.020(10~50MHz)

0.006(50~500MHz)

0.006(0.05~13.5GHz)

0.006(13.5~20GHz)

0.012(20~26.5GHz)

IF Bandwidth 1Hz~5MHz
Amplitude Display Resolution  

0.001dB/div

Phase     Display Resolution 0.01°/div
Setting Requirement   of

Reference  Level

 

-500~+500dB

Amplitude
Setting Requirement of Reference Level

Phase

 

-500~+500°

General Characteristic
Port Connectors 3.5mm (Male), 50 ohm system impedance
Number          of Measuring Ports 3672A/B Standard configuration:2 Ports;3672A/B-400 Option:4 Ports
Peripheral

Interface

USB, GPIB, VGA, LAN
Operating System Windows 7
Display 12.1-Inch High Resolution Touch Screen
Size W´H´D=426mm×266mm×550mm (excluding support and handle) W´H´D=516mm×280mm×640mm (including handle, support and back foot)
Max.        Power

Consumption

400w
Max. Weight 42kg

3672C/D Technical Specifications

Frequency Characteristic
Frequency Range 10MHz~43.5/50GHz
Frequency Resolution 1Hz
Frequency

Accuracy

±1×10-7(23℃±3℃)
Port Harmonic Suppression Typical Value
Harmonic Suppression     on Port 1 And 3 -48dBc(0.01~4GHz)

-57dBc(4~13.5GHz)

-57dBc(13.5~50GHz)

-51dBc(0.01~4GHz)

-60dBc(4~13.5GHz)

-60dBc(13.5~50GHz)

Harmonic Suppression     on Port 2 And 4 -13dBc(0.01~4GHz)

-18dBc(4~13.5GHz)

-57dBc(13.5~50GHz)

-13dBc(0.01~4GHz)

-21dBc(4~13.5GHz)

-60dBc(13.5~50GHz)

Port Power Characteristic Typical Value
32dB(10~50MHz) 41dB(10~500MHz)
29dB(0.05~4GHz) 40dB(0.5~4GHz)
Power       Sweep Range 28dB(4~13.5GHz)

30dB(13.5~40GHz)

36dB(4~13.5GHz)

38dB(13.5~40GHz)

27dB(40~47GHz) 36dB(40~47GHz)
15dB(47~50GHz) 23dB(47~50GHz)
-1dBm(10~50MHz)(Filter Mode)
0dBm(0.05~4GHz)(Filter Mode) +13dBm(10~50MHz)(High Power
+8dBm(10~50MHz)(High Power Mode)
Mode) +9dBm(0.05~4GHz)(High Power
Max. Output Power (Standar d Configu ration, Option

400)

Port 1, 3 +5dBm(0.05~4GHz)    (High    Power Mode)

+5dBm(4~13.5GHz)

+7dBm(13.5~40GHz)

+5dBm(40~47GHz)

-7dBm(47~50GHz)

Mode)

+10dBm(4~13.5GHz)

+13dBm(13.5~40GHz)

+10dBm(40~47GHz) 0dBm(47~50GHz)

+11dBm(10~50MHz)

+9dBm(0.05~4GHz)

+16dBm(10~50MHz)

+15dBm(0.05~4GHz)

Port 2, 4 +6dBm(4~13.5GHz)

+7dBm(13.5~40GHz)

+13dBm(4~13.5GHz)

+12dBm(13.5~40GHz)

+5dBm(40~47GHz) +9dBm(40~47GHz)
-7dBm(47~50GHz) -1dBm(47~50GHz)
-2dBm(10~50MHz)(Filter Mode)
-1dBm(0.05~4GHz)(Filter Mode) +12dBm(10~50MHz)(High Power
+7dBm(10~50MHz)(High Power Mode)
Max. Output Power (Option 201,

401,

402)

 

Port 1, 3

Mode)

+4dBm(0.05~4GHz)(High Power Mode)

+3dBm(4~13.5GHz)

+5dBm(13.5~40GHz)

+2dBm(40~47GHz)

-10dBm(47~50GHz)

+8dBm(0.05~4GHz)(High Power Mode)

+9dBm(4~13.5GHz)

+12dBm(13.5~40GHz)

+9dBm(40~47GHz)

-1dBm(47~50GHz)

Port 2, 4 +10dBm(10~50MHz)

+8dBm(0.05~4GHz)

+4dBm(4~13.5GHz)

+15dBm(10~50MHz)

+14dBm(0.05~4GHz)

+12dBm(4~13.5GHz)

 

+5dBm(13.5~40GHz)

+2dBm(40~47GHz)

-10dBm(47~50GHz)

+11dBm(13.5~40GHz)

+8dBm(40~47GHz)

-2dBm(47~50GHz)

1dB Compression Level  

/

 

+10dBm

Pulse Characteristic Typical Value
Pulse         Width Setting Range 33ns~60s 20ns~60s
Pulse Transition Time

(10%-90%)

 

30ns

 

20ns

Pulse        On/Off Ratio 64dB(0.01~4GHz)

80dB(4~40GHz)

80dB(40~50GHz)

Network Parameter Characteristics Typical Value
74dB(0.01~1GHz) 105dB(0.01~1GHz)
119dB(1~13.5GHz) 133dB(1~13.5GHz)
System Dynamic Range 115dB(13.5~26.5GHz)

110dB(26.5~35GHz)

126dB(13.5~26.5GHz)

120dB(26.5~35GHz)

105dB(35~47GHz) 116dB(35~47GHz)
90dB(47~50GHz) 103dB(47~50GHz)
Effective Directivity 42dB(0.01~13.5GHz)

38dB(13.5~40GHz)

36dB(40~50GHz)

50dB(0.01~13.5GHz)

45dB(13.5~40GHz)

42dB(40~50GHz)

36dB(0.01~2GHz) 43dB(0.01~2GHz)
Effective Source Match 31dB(2~13.5GHz)

28dB(13.5~40GHz)

34dB(2~13.5GHz)

33dB(13.5~40GHz)

27dB(40~50GHz) 33dB(40~50GHz)
Effective     Load Match 42dB(0.01~13.5GHz)

37dB(13.5~40GHz)

35dB(40~50GHz)

60dB(0.01~13.5GHz)

56dB(13.5~40GHz)

51dB(40~50GHz)

Reflection Tracking ±0.04dB(0.01~13.5GHz)

±0.03dB(13.5~40GHz)

±0.04dB(40~50GHz)

±0.010dB(0.01~13.5GHz)

±0.010dB(13.5~40GHz)

±0.020dB(40~50GHz)

Transmission Tracking ±0.1dB(0.01~13.5GHz)

±0.16dB(13.5~40GHz)

±0.20dB(40~50GHz)

±0.012dB(0.01~13.5GHz)

±0.015dB(13.5~40GHz)

±0.020dB(40~50GHz)

Others Typical Value
Amplitude Trace 0.050(10~50MHz)

0.020(50~500MHz)

0.005(0.5~13.5GHz)

0.004(13.5~26.5GHz)

0.008(26.5~50GHz)

0.0060(10~50MHz)

0.0020(50~500MHz)

0.0010(0.5~13.5GHz)

0.0009(13.5~26.5GHz)

0.0040(26.5~50GHz)

Noise
dB rms(1kHz IF
Bandwidth)
Phase          Trace 0.900(10~50MHz)

0.700(50~500MHz)

0.040(0.5~13.5GHz)

0.050(13.5~26.5GHz)

0.060(26.5~50GHz)

0.040(10~50MHz)

0.010(50~500MHz)

0.005(0.5~13.5GHz)

0.020(13.5~26.5GHz)

0.030(26.5~50GHz)

Noise
deg rms (1kHz IF
Bandwidth)
IF Bandwidth 1Hz~5MHz
Amplitude Display 0.001dB/div

 

Resolution
Phase       Display Resolution 0.01°/div
Setting Requirement     of Reference    Level Amplitude  

-500~+500dB

Setting Requirement     of Reference    Level

Phase

 

-500~+500°

General Characteristic
Port Connectors 2.4mm (Male), 50 ohm system impedance
Number            of Measuring Ports 3672C/D Standard configuration:2 ports, 3672C/D-400 Option: 4 ports
Peripheral

Interface

USB, GPIB, VGA, LAN
Operating System Windows 7
Display 12.1-Inch High Resolution Touch Screen
Size W´H´D=426mm×266mm×600mm (excluding support and handle) W´H´D=516mm×280mm×690mm (including handle, support and back foot)
Max.          Power

Consumption

500w
Max. Weight 47kg

 

3672E Technical Specifications

Frequency Characteristics
Frequency Range 10MHz~67GHz
Frequency Resolution 1Hz
Frequency

Accuracy

±1×10-7(23℃±3℃)
Port Harmonic Suppression Typical Value
Harmonic Suppression     on Port 1 and 3 -48dBc(0.01~4GHz)

-57dBc(4~67GHz)

-51dBc(0.01~4GHz)

-60dBc(4~67GHz)

Harmonic Suppression     on Port 2 and 4 -13dBc(0.01~4GHz)

-18dBc(4~13.5GHz)

-57dBc(13.5~67GHz)

-13dBc(0.01~4GHz)

-21dBc(4~13.5GHz)

-60dBc(13.5~67GHz)

Port Power Characteristics Typical Value
 

 

Power       Sweep Range

32dB(10~50MHz)

29dB(0.05~4GHz)

28dB(4~26.5GHz)

29dB(26.5~35GHz)

26dB(35~40GHz)

25dB(40~67GHz)

42dB(10~500MHz)

38dB(0.5~4GHz)

36dB(4~26.5GHz)

35dB(26.5~35GHz)

34dB(35~40GHz)

32dB(40~67GHz)

 

 

 

 

Max. Output Power (standar d configur ation, option 400)

 

 

 

 

Port 1, 3

-1dBm(10~50MHz)(Filter mode) 0dBm(0.05~4GHz)(Filter mode)

+8dBm(10~50MHz)(High power mode)

+5dBm(0.05~4GHz )( High power mode)

+1dBm(4~13.5GHz)

+5dBm(13.5~26.5GHz)

+3dBm(26.5~40GHz)

+5dBm(40~67GHz)

 

+16dBm(10~50MHz)(High power mode)

+10dBm(0.05~4GHz)(High power mode)

+9dBm(4~13.5GHz)

+11dBm(13.5~26.5GHz)

+10dBm(26.5~40GHz)

+9dBm(40~67GHz)

 

 

Port 2, 4

+8dBm(10~50MHz)

+5dBm(0.05~4GHz)

+1dBm(4~13.5GHz)

+5dBm(13.5~26.5GHz)

+3dBm(26.5~40GHz)

+5dBm(40~67GHz)

+16dBm(10~50MHz)

+15dBm(0.05~4GHz)

+10dBm(4~13.5GHz)

+11dBm(13.5~26.5GHz)

+9dBm(26.5~40GHz)

+8dBm(40~67GHz)

 

 

 

 

Max. Output Power (option 201,

401,

402)

 

 

 

 

Port 1, 3

-2dBm(10~50MHz)(Filter Mode)

-1dBm(0.05~4GHz)(Filter Mode)

+7dBm(10~50MHz)(High Power Mode)

+4dBm(0.05~4GHz)(High Power Mode)

-2dBm(4~13.5GHz)

+3dBm(13.5~26.5GHz) 0dBm(26.5~67GHz)

 

+15dBm(10~50MHz)(High Power Mode)

+9dBm(0.05~4GHz)(High Power Mode)

+6dBm(4~13.5GHz)

+7dBm(13.5~26.5GHz)

+4dBm(26.5~67GHz)

 

Port 2, 4

+7dBm(10~50MHz)

+4dBm(0.05~4GHz)

-2dBm(4~13.5GHz)

+3dBm(13.5~26.5GHz) 0dBm(26.5~67GHz)

+15dBm(10~50MHz)

+14dBm(0.05~4GHz)

+9dBm(4~13.5GHz)

+10dBm(13.5~26.5GHz)

+5dBm(26.5~67GHz)

 

1dB

Compression Level

 

/

 

+10dBm

Pulse Characteristics Typical Value
Pulse         Width Setting Range 33ns~60s 20ns~60s
Pulse Transition Time (10%-90%) 30ns 20ns
Pulse Ratio on/off 64dB(0.01~4GHz)

80dB(4~67GHz)

Network Parameter Characteristic Typical Value
74dB(0.01~1GHz) 100dB(0.01~1GHz)
100dB(1~4GHz) 125dB(1~4GHz)
System Dynamic Range 120dB(4~10GHz)

112dB(10~26.5GHz)

108dB(26.5~35GHz)

125dB(4~10GHz)

120dB(10~26.5GHz)

115dB(26.5~35GHz)

105dB(35~50GHz) 112dB(35~50GHz)
100dB(50~67GHz) 105dB(50~67GHz)
35dB(0.01~2GHz) 50dB(0.01~2GHz)
Effective Directivity 41dB(2~13.5GHz)

34dB(13.5~40GHz)

50dB(2~13.5GHz)

50dB(13.5~40GHz)

32dB(40~67GHz) 42dB(40~67GHz)
35dB(0.01~2GHz) 60dB(0.01~2GHz)
Effective Match Load 41dB(2~13.5GHz)

33dB(13.5~40GHz)

50dB(2~13.5GHz)

50dB(13.5~40GHz)

30dB(40~67GHz) 45dB(40~67GHz)
±0.05dB(0.01~2GHz) ±0.005dB(0.01~2GHz)
Reflection Tracking ±0.06dB(2~13.5GHz)

±0.08dB(13.5~40GHz)

±0.005dB(2~13.5GHz)

±0.008dB(13.5~40GHz)

±0.10dB(40~67GHz) ±0.010dB(40~67GHz)
±0.10dB(0.01~2GHz) ±0.005dB(0.01~2GHz)
Transmission Tracking ±0.11dB(2~13.5GHz)

±0.16dB(13.5~40GHz)

±0.006dB(2~13.5GHz)

±0.015dB(13.5~40GHz)

±0.20dB(40~67GHz) ±0.020dB(40~67GHz)
Others Typical Value
Amplitude Trace 0.050(10~50MHz)

0.020(50~500MHz)

0.005(0.5~13.5GHz)

0.004(13.5~26.5GHz)

0.020(26.5~67GHz)

0.0090(10~50MHz)

0.0020(50~500MHz)

0.0008(0.5~13.5GHz)

0.0008(13.5~26.5GHz)

0.0050(26.5~67GHz)

Noise
dB rms(1kHz IF
bandwidth)
Phase Trace 0.90(10~50MHz)

0.70(50~500MHz)

0.04(0.5~13.5GHz)

0.05(13.5~26.5GHz)

0.10(26.5~67GHz)

0.010(10~50MHz)

0.010(50~500MHz)

0.006(0.5~13.5GHz)

0.007(13.5~26.5GHz)

0.030(26.5~67GHz)

Noise
deg rms(1kHz IF
bandwidth)
IF Bandwidth 1Hz~5MHz
Amplitude Display Resolution  

0.001dB/div

Phase       Display

Resolution

0.01°/div
Setting -500~+500dB

 

Requirement     of

Reference    Level Amplitude

Setting Requirement     of

Reference    Level Phase

 

-500~+500°

General Characteristics
Port Connectors 1.85mm (Male), 50 ohm system impedance
Number           of measuring Ports 3672E Standard configuration:2 ports, 3672E-400 Option: 4 ports
Peripheral Interface USB, GPIB, VGA, LAN
Operating System Windows 7
Display 12.1-Inch High Resolution Touch Screen
Size W´H´D=426mm×266mm×600mm (excluding support and handle) W´H´D=516mm×280mm×690mm (including handle, support and back foot)
Max.          Power

Consumption

500W
Max. Weight 50 kg

 

Ordering Information 

Main Unit Description
3672A Vector Network Analyzer (10MHZ ~ 13.5GHZ)
3672B Vector Network Analyzer (10MHZ ~ 26.5GHZ)
3672C Vector Network Analyzer (10MHZ ~ 43.5GHZ)
3672D Vector Network Analyzer (10MHZ ~ 50GHZ)
3672E Vector Network Analyzer (10MHZ ~ 67GHZ)

 Standard Package

No. Description Remarks
1 Power Cord Assembly Standard three-prong power cord
2 USB Keyboard/Mouse
3 User Manual
4 Certificate of Conformity
5 Aluminum Alloy Box

 Options

3672A Options

Model Description Remarks
 3672A-201 2-Port      Programmable      Step Attenuator Set two 70dB programmable step attenuators for the source path, and two 35dB programmable step attenuators for the receiver path
3672A-400 4-Port Measurement Two-source

configuration

stimulus four-port VNA
 3672A-401  4-Port      Programmable      Step Attenuator Set four 70dB programmable step attenuators for the source path, and four 35dB programmable step attenuators for the receiver path (Option 400 is needed)
3672A-402 Active               Inter-modulation Measurement For inter-modulation signal measurement of amplifier (Option 400 is needed)
3672A-006 English Options Key, Front Panel, Label, Operation System
3672A-008 Pulse Measurement For pulse S-parameter measurement
 3672A-S10  Time Domain Measurement For time-domain test, can locate and analyze the discontinuous positions in devices, fixtures or cables.
 3672A-S80  Frequency Offset Measurement For frequency offset measurement. millimeter-wave frequency extension main unit needs this option
3672A-S82 Mixer Scalar Measurement For the scalar parameter measurement of mixers (Option 400 is needed)
3672A-S83 Mixer Vector Measurement For the vector parameter measurement of mixers (Option 400 is needed)
3672A-S84 Embedded LO Frequency

Converter Measurement

For the measurement of embedded LO frequency converters (Option 400, S82 or S83 are needed)
 3672A-S86 Gain Compression Two-Dimension Sweep Measurement For the gain compression two-dimension sweep test of amplifier
31121 3.5mm Calibration Kit For calibration of the analyzer
FB0HA0HB025.0 3.5mm Test cable For measurement of the analyzer
FB0HA0HC025.0 3.5mm Test cable For measurement of the analyzer
20403 E-Cal Kit For        calibration        of        the        analyzer (10MHz-26.5GHz, 2 ports)
20405 E-Cal Kit For calibration of the analyzer (10MHz-20GHZ, 4 ports)
87232 Usb Power Probe For 402, S82, S86 Options in the process of

power calibration(50MHz-26.5GHZ)

3672B Options

Model Description Remarks
 3672B-201 2-Port      Programmable      Step Attenuator Set Two 70dB programmable step attenuators for the source path, and two 35dB programmable step attenuators for the receiver path
3672B-400 4-Port Measurement Two-source

configuration

stimulus four-port VNA
 3672B-401  4-Port      Programmable      Step Attenuator Set four 70dB programmable step attenuators for the source path, and four 35dB programmable step attenuators for the receiver path (Option 400 is needed)
3672B-402 Active               Inter-modulation Measurement For inter-modulation signal measurement of amplifier (Option 400 is needed)
3672B-006 English Options Key, Front Panel, Label, Operation System
3672B-008 Pulse Measurement For pulse S-parameter measurement
 3672B-S10  Time Domain Measurement For time-domain test, can locate and analyze the discontinuous positions in devices, fixtures or cables.
 3672B-S80  Frequency Offset Measurement For frequency offset measurement. millimeter-wave frequency extension main unit needs this option
3672B-S82 Mixer Scalar Measurement For the scalar parameter measurement of mixers (Option 400 is needed)
3672B-S83 Mixer Vector Measurement For the vector parameter measurement of mixers (Option 400 is needed)
3672B-S84 Embedded       LO       Frequency Converter Measurement For the measurement of embedded LO frequency converters(Option 400, S82 or S83 are needed)
 3672B-S86 Gain Compression Two-Dimension Sweep Measurement For the gain compression two-dimension sweep test of amplifier
31121 3.5mm Calibration Kit For calibration of the analyzer
FB0HA0HB025.0 3.5mm Test cable For measurement of the analyzer
FB0HA0HC025.0 3.5mm Test cable For measurement of the analyzer
20403 E-Cal Kit For        calibration        of        the        analyzer (10MHZ-26.5GHZ, 2 ports)
20405 E-Cal Kit For calibration of the analyzer (10MHZ-20GHZ, 4 ports)
87232 USB Power Probe For 402, S82, S86 Options in the process of

power calibration(50MHZ-26.5GHZ)

3672C Options

Model Description Remarks
 3672C-201 2-Port      Programmable      Step Attenuator Set two 60dB programmable step attenuators for the source path, and two 35dB programmable step attenuators for the receiver path
3672C-400 4-Port Measurement Two-source

configuration

stimulus four-port VNA
 3672C-401  4-Port      Programmable      Step Attenuator Set four 60dB programmable step attenuators for the source path, and four 35dB programmable step attenuators for the receiver path (Option 400 is needed)
3672C-402 Active Inter-modulation Measurement For inter-modulation signal measurement of amplifier (Option 400 is needed)
3672C-006 English Options Key, Front Panel, Label, Operation System
3672C-008 Pulse Measurement For pulse S-parameter measurement
 3672C-S10  Time Domain Measurement For time-domain test, can locate and analyze the discontinuous positions in devices, fixtures or cables.
 3672C-S80  Frequency Offset Measurement For frequency  offset measurement. millimeter-wave frequency extension main unit needs this option
3672B-S82 Mixer Scalar Measurement For the scalar parameter measurement of mixers (Option 400 is needed)
3672B-S83 Mixer Vector Measurement For the vector parameter measurement of mixers (Option 400 is needed)
3672B-S84 Embedded LO Frequency

Converter Measurement

For the measurement of embedded LO frequency converters (Option 400, S82 or S83 are needed)
 3672C-S86 Gain Compression Two-Dimension Sweep Measurement For the gain compression two-dimension sweep test of amplifier
31123 2.4mm Calibration Kit For calibration of the analyzer
FE0BN0BM025.0 2.4mm Test cable For measurement of the analyzer
FE0BN0BL025.0 2.4mm Test cable For measurement of the analyzer
20404 E-Cal Kit For calibration of the analyzer (10MHz-50GHz 2 ports)
87233 USB Power Probe For 402, S82, S86 Options in the process of power calibration (50MHz-40GHz)

3672D Options

Model Description Remarks
 3672D-201 2-Port      Programmable      Step Attenuator Set two 60dB programmable step attenuators for the source path, and two 35dB programmable step attenuators for the receiver path
3672D-400 4-Port Measurement Two-source configuration stimulus four-port VNA
 3672D-401  4-Port      Programmable      Step Attenuator Set four 60dB programmable step attenuators for the source path, and four 35dB programmable step attenuators for the receiver path (Option 400 is needed)
3672D-006 English Options Key, Front Panel, Label, Operation System
3672D-008 Pulse Measurement For pulse S-parameter measurement
 3672D-S10  Time Domain Measurement For time-domain test, can locate and analyze the discontinuous positions in devices, fixtures or cables.
 3672D-S80  Frequency Offset Measurement For frequency offset measurement. millimeter-wave frequency extension main unit needs this option
3672B-S82 Mixer Scalar Measurement For the scalar parameter measurement of mixers (Option 400 is needed)
3672B-S83 Mixer Vector Measurement For the vector parameter measurement of mixers (Option 400 is needed)
3672B-S84 Embedded       LO       Frequency Converter Measurement For the measurement of embedded LO frequency converters(Option 400, S82 or S83 are needed)
 3672D-S86 Gain Compression Two Dimension Sweep Measurement For the gain compression two-dimension sweep test of amplifier
31123A 2.4mm Calibration Kit For calibration of the analyzer
FE0BN0BM025.0 2.4mm Test cable For measurement of the analyzer
FE0BN0BL025.0 2.4mm Test cable For measurement of the analyzer
20404 E-Cal Kit For calibration of the analyzer (10MHZ-50GHZ 2 ports)

3672E Options

Model Description Remarks
 3672E-201 2-Port     Programmable     Step Attenuator Set two 50dB programmable step attenuators for the source path, and two 50dB programmable step attenuators for the receiver path
3672E-400 4-Port Measurement Two-source stimulus four-port VNA configuration
 

3672E-401

 

4-Port     Programmable     Step Attenuator

Set four 50dB programmable step attenuator s for the source path, and four 50dB programmable step attenuator s for the receiver path (Option 400 is needed)
3672E-402 Active             Inter-modulation Measurement For inter-modulation signal measurement of amplifier (Option 400 is needed)
3672E-006 English Options Key, Front Panel, Label, Operation System
3672E-008 Pulse Measurement For pulse S-parameter measurement
 

3672E-S10

 

Time-Domain Measurement

For time-domain test, can locate and analyze the discontinuous positions in devices, fixtures or cables.
 

3672E-S80

 

Frequency Offset Measurement

For frequency offset measurement. millimeter-wave frequency extension main unit needs this option
3672E-S82 Mixer Scalar Measurement For the scalar parameter measurement of mixers (Option 400 is needed)
3672E-S83 Mixer Vector Measurement For the vector parameter measurement of mixers (Option 400 is needed)
3672E-S84 Embedded  LO Frequency Converter Measurement For the measurement of embedded LO frequency converters(Option 400, S82 or S83 are needed)
 

3672E-S86

Gain Compression Two-Dimension  Sweep Measurement For the gain compression two-dimension sweep test of amplifier
31128 1.85mm Calibration Kit For calibration of the analyzer
N4697F/ FF0CN0CM025.0

FF0CN0CL025.0

 

1.85mm Test cable

 

For measurement of the analyzer

20409 E-Cal Kit For calibration of the analyzer (10MHZ-67GHZ, 2 ports)

 

 

 

has been added to your cart: