Description

3672E Vector Network Analyzer (10MHZ ~ 67GHZ)

3672E Vector Network Analyzer (10MHZ ~ 67GHZ)

3672A/B/C/D/E Vector Network Analyzer (10 MHz ~ 67 GHz)

Product Overview

3672 Series Vector Network Analyzers include 3672 A (10 MHz~13.5 GHz), 3672B (10 MHz~26.5 GHz), 3672 C (10 MHz~43.5 GHz), 3672D (10 MHz~50 GHz) and 3672E (10 MHz~67 GHz). In terms of hardware, comparing to last generation, the brand-new design concept and technical proposal have upgraded key performance indexes (KPI) of the complete machine such as sweep speed and dynamic range etc.; in terms of software, the embedded computer system (ECS) with high-performance microprocessor chip and the platform based on Windows operating system has greatly improved inter-connectivity and usability of the complete machine. 3672 analyzers provide multiple calibration types including frequency response, single port, response isolation, enhanced response and full dual-port, electronic calibration etc., offer various display formats such as logarithmic amplitude, linear amplitude, standing-wave, phase, group delay, Smith chart and polar coordinates, etc.

They are designed with several standard interfaces: USB, LAN, GPIB and VGA etc. Besides all measurement functions same as traditional vector network analyzer, through configuration of functional options, 3672 analyzers are also capable of multi-functional & comprehensive parameter test of mixer/converter, gain compression two-dimensional sweep and pulse S-parameters, as well as accuracy measurement of amplitude-frequency characteristics, phase-frequency characteristics and group delay used in the field of transmitting/receiving (T/R) module measurement, dielectric material properties measurement, microwave pulse characteristics measurement and optoelectronic properties measurement, which are indispensable instruments for scientific research and manufacturing process of radar, communication, and navigation systems.

Main Characteristics

  • Flexible and optional calibration types, compatible with multiple calibration kits
  • Support multi-window, multi-channel tests, fast implementation of complex test scheme
  • Available in multiple display formats such as logarithmic amplitude, linear amplitude, standing-wave, phase, Smith chart
  • With USB, GPIB, LAN and VGA display interface
  • 1 inch high resolution touch screen
  • Record/run, one-click operation greatly simplifies the measurement setting steps and improves the efficiency
  • Available in functions as pulse S parameter measurement, time-domain measurement, mixer measurement, gain compression two-dimensional sweep measurement, millimeter-wave frequency extension, antenna & RCS measurement and receiving .

Humanized user interface for easy operation, which can improve the efficiency

Parameters can be quickly input through activated input toolbar.

It can improve the test efficiency to setup the limit line and segment sweep value for production line.

The soft panel can be put on left or right side of the screen. Or it can be hidden for operation convenience.

Flexible and optional calibration types, compatible with multiple calibration kits

3672 Series of Vector Network Analyzers provide multiple calibration types, including guided calibration (automatic calibration), unguided calibration (using mechanical calibration kit to conduct through response calibration, through response & isolation calibration, single port calibration, enhanced response calibration, full two-port SOLT calibration, TRL calibration) and electronic calibration (E-Cal) etc.. Users can select calibration kits, such as coaxial 3.5 mm calibration kit and electronic calibration kit based on test requirements, which greatly facilitates testing on devices with different interfaces.

Multiple windows to display all measuring channels

The analyzers possess functions of multi-channel and multi-window display, support up to 64 channels. Maximum 16 measuring windows can be simultaneously displayed, and each window can simultaneously display up to 8 test traces, which makes the observation results more visible and the operation more convenient.

Rich peripheral interfaces, flexible and practical 

Adopting the software & hardware platform consisting of embedded computer module compatible with PC and Windows operation system, 3672 Series of Vector Network Analyzers realize the perfect combination of the instrument and PC. Users can use the rich I/O interfaces (including GPIB, USB, and LAN etc.) to complete the optimum selection of data communication.

Low trace noise, high test accuracy

Time-domain analysis can comprehensively characterize the design

With time-domain options, 3672 Series of Vector Network Analyzers can realize the switching of measurement results between frequency-domain and time-domain, which can be used to identify the discontinuous points of devices, fixtures or cables to realize accurate fault location.

Automatic test

Calibration is complicated: short-circuiter, open-circuiter, load, through – SO PROFESSIONAL! Set up the same parameters over and over again – VERY BORING!

Products need to be tested under harsh conditions – BUT PEOPLE NEEDN’T!

Setting changing and data recording need to be done at set intervals – UNFORTUNATELY,I AM NOT A TIMER!

3672 Series of Vector Network Analyzers can provide you integrated automatic test solutions including automatic calibration, automatic measurement, automatic reading and automatic printing.

Flexible and multiple control modes are provided through GPIB, LAN, and USB interfaces. All you need to do is to finish the interconnection of equipment and send the command.

What benefits does automatic test bring for you?

  • Simple control method: one LAN line, one GPIB card
  • Effectively lower the test cost, liberate limited human resources
  • Finish more tests in effective time, greatly shorten the development period
  • Finish the task impossible for manpower, such as accurate timing, tests under complex environment

 

 

 

Additional information

Weight47 kg
Dimensions51.6 × 64.0 × 28.0 cm

3672A/B Technical Specifications

Frequency Characteristic
Frequency Range10MHz~13.5/26.5GHz
Frequency Resolution1Hz
Frequency

Accuracy

±1×10-7(23℃±3℃)
Port Harmonic SuppressionTypical Value
Harmonic Suppression on Port 1 And 3-48dBc(0.01~4GHz)

-57dBc(4~13.5GHz)

-57dBc(13.5~26.5GHz)

-51dBc(0.01~4GHz)

-60dBc(4~13.5GHz)

-60dBc(13.5~26.5GHz)

Harmonic Suppression On Port 2 And 4-13dBc(0.01~4GHz)

-18dBc(4~13.5GHz)

-18dBc(13.5~26.5GHz)

-13dBc(0.01~4GHz)

-21dBc(4~13.5GHz)

-21dBc(13.5~26.5GHz)

Port Power CharacteristicTypical Value
 

 

Power      Sweep Range

33dB(10~500MHz)

30dB(0.5~4GHz)

34dB(4~7GHz)

31dB(7~13.5GHz)

29dB(13.5~20GHz)

25dB(20~26.5GHz)

42dB(10~500MHz)

37dB(0.5~4GHz)

42dB(4~7GHz)

41dB(7~13.5GHz)

38dB(13.5~20GHz)

35dB(20~26.5GHz)

 

 

 

 

Max. Output Power (Standard Configura tion, Option 400)

 

 

 

 

Port 1, 3

0dBm(0.01~4GHz)(Filter Mode)

+9dBm(10~50MHz)(High Power Mode)

+6dBm(0.05~4GHz)(High Power Mode)

+12dBm(4~7GHz)

+8dBm(7~13.5GHz)

+6dBm(13.5~20GHz)

+4dBm(20~26.5GHz)

+16dBm(10~50MHz)(High Power Mode)

+11dBm(0.05~4GHz)(High Power Mode)

+16dBm(4~7GHz)

+14dBm(7~13.5GHz)

+11dBm(13.5~20GHz)

+9dBm(20~26.5GHz)

 

 

Port 2, 4

+13dBm(10~50MHz)

+13dBm(0.05~4GHz)

+10dBm(4~7GHz)

+9dBm(7~13.5GHz)

+6dBm(13.5~20GHz)

+2dBm(20~26.5GHz)

+16dBm(10~50MHz)

+16dBm(0.05~4GHz)

+16dBm(4~7GHz)

+15dBm(7~13.5GHz)

+13dBm(13.5~20GHz)

+8dBm(20~26.5GHz)

 

 

 

Max. Output Power (Option 201, 401,

402)

 

 

 

 

Port 1, 3

-1dBm(0.01~4GHz)(Filter Mode)

+8dBm(10~50MHz)(High Power Mode)

+5dBm(0.05~4GHz)(High Power Mode)

+10dBm(4~7GHz)

+6dBm(7~13.5GHz)

+4dBm(13.5~20GHz)

+2dBm(20~26.5GHz)

+15dBm(10~50MHz)(High Power Mode)

+10dBm(0.05~4GHz)(High Power Mode)

+15dBm(4~7GHz)

+13dBm(7~13.5GHz)

+10dBm(13.5~20GHz)

+8dBm(20~26.5GHz)

Port 2, 4+12dBm(10~50MHz)

+12dBm(0.05~4GHz)

+15dBm(10~50MHz)

+15dBm(0.05~4GHz)

+9dBm(4~7GHz)

+8dBm(7~13.5GHz)

+5dBm(13.5~20GHz) 0dBm(20~26.5GHz)

+15dBm(4~7GHz)

+14dBm(7~13.5GHz)

+12dBm(13.5~20GHz)

+7dBm(20~26.5GHz)

1dB

Compression Level

 

/

 

+13dBm

Pulse CharacteristicTypical Value
Pulse               Width Setting Range33ns~60s20ns~60s
Pulse Transition Time

(10%-90%)

 

30ns

 

20ns

Pulse              On/Off Ratio64dB(0.01~4GHz)

80dB(4~26.5GHz)

Network Parameter CharacteristicTypical Value
 

 

System Dynamic Range

90dB(0.01~1GHz)

120dB(1~4GHz)

127dB(4~10GHz)

120dB(10~20GHz)

115dB(20~24GHz)

110dB(24~26.5GHz)

100dB(0.01~1GHz)

128dB(1~4GHz)

135dB(4~10GHz)

132dB(10~20GHz)

129dB(20~24GHz)

125dB(24~26.5GHz)

Effective Directivity48dB(0.01~2GHz)

44dB(2~26.5GHz)

60dB(0.01~2GHz)

53dB(2~26.5GHz)

Effective Source Match40dB(0.01~2GHz)

30dB(2~26.5GHz)

46dB(0.01~2GHz)

36dB(2~26.5GHz)

Effective   Load Match48dB(0.01~2GHz)

44dB(2~26.5GHz)

60dB(0.01~2GHz)

51dB(2~26.5GHz)

Reflection Tracking±0.04dB(0.01~2GHz)

±0.05dB(2~26.5GHz)

±0.004dB(0.01~2GHz)

±0.010dB(2~26.5GHz)

Transmission Tracking±0.10dB(0.01~2GHz)

±0.12dB(2~26.5GHz)

±0.005dB(0.01~2GHz)

±0.015dB(2~26.5GHz)

OthersTypical Value
Amplitude Trace Noise

dB rms(1kHz If Bandwidth)

0.0500(10~50MHz)

0.0070(50~500MHz)

0.0020(0.5~13.5GHz)

0.0030(13.5~20GHz)

0.0050(20~26.5GHz)

0.0020(10~50MHz)

0.0008(50~500MHz)

0.0009(0.05~13.5GHz)

0.0008(13.5~20GHz)

0.0010(20~26.5GHz)

Phase        Trace Noise

deg rms(1kHz IF    Bandwidth)

0.200(10~50MHz)

0.051(50~500MHz)

0.042(0.5~13.5GHz)

0.054(13.5~20GHz)

0.054(20~26.5GHz)

0.020(10~50MHz)

0.006(50~500MHz)

0.006(0.05~13.5GHz)

0.006(13.5~20GHz)

0.012(20~26.5GHz)

IF Bandwidth1Hz~5MHz
Amplitude Display Resolution 

0.001dB/div

Phase     Display Resolution0.01°/div
Setting Requirement   of

Reference  Level

 

-500~+500dB

Amplitude
Setting Requirement of Reference Level

Phase

 

-500~+500°

General Characteristic
Port Connectors3.5mm (Male), 50 ohm system impedance
Number          of Measuring Ports3672A/B Standard configuration:2 Ports;3672A/B-400 Option:4 Ports
Peripheral

Interface

USB, GPIB, VGA, LAN
Operating SystemWindows 7
Display12.1-Inch High Resolution Touch Screen
SizeW´H´D=426mm×266mm×550mm (excluding support and handle) W´H´D=516mm×280mm×640mm (including handle, support and back foot)
Max.        Power

Consumption

400w
Max. Weight42kg

3672C/D Technical Specifications

Frequency Characteristic
Frequency Range10MHz~43.5/50GHz
Frequency Resolution1Hz
Frequency

Accuracy

±1×10-7(23℃±3℃)
Port Harmonic SuppressionTypical Value
Harmonic Suppression     on Port 1 And 3-48dBc(0.01~4GHz)

-57dBc(4~13.5GHz)

-57dBc(13.5~50GHz)

-51dBc(0.01~4GHz)

-60dBc(4~13.5GHz)

-60dBc(13.5~50GHz)

Harmonic Suppression     on Port 2 And 4-13dBc(0.01~4GHz)

-18dBc(4~13.5GHz)

-57dBc(13.5~50GHz)

-13dBc(0.01~4GHz)

-21dBc(4~13.5GHz)

-60dBc(13.5~50GHz)

Port Power CharacteristicTypical Value
32dB(10~50MHz)41dB(10~500MHz)
29dB(0.05~4GHz)40dB(0.5~4GHz)
Power       Sweep Range28dB(4~13.5GHz)

30dB(13.5~40GHz)

36dB(4~13.5GHz)

38dB(13.5~40GHz)

27dB(40~47GHz)36dB(40~47GHz)
15dB(47~50GHz)23dB(47~50GHz)
-1dBm(10~50MHz)(Filter Mode)
0dBm(0.05~4GHz)(Filter Mode)+13dBm(10~50MHz)(High Power
+8dBm(10~50MHz)(High PowerMode)
Mode)+9dBm(0.05~4GHz)(High Power
Max. Output Power (Standar d Configu ration, Option

400)

Port 1, 3+5dBm(0.05~4GHz)    (High    Power Mode)

+5dBm(4~13.5GHz)

+7dBm(13.5~40GHz)

+5dBm(40~47GHz)

-7dBm(47~50GHz)

Mode)

+10dBm(4~13.5GHz)

+13dBm(13.5~40GHz)

+10dBm(40~47GHz) 0dBm(47~50GHz)

+11dBm(10~50MHz)

+9dBm(0.05~4GHz)

+16dBm(10~50MHz)

+15dBm(0.05~4GHz)

Port 2, 4+6dBm(4~13.5GHz)

+7dBm(13.5~40GHz)

+13dBm(4~13.5GHz)

+12dBm(13.5~40GHz)

+5dBm(40~47GHz)+9dBm(40~47GHz)
-7dBm(47~50GHz)-1dBm(47~50GHz)
-2dBm(10~50MHz)(Filter Mode)
-1dBm(0.05~4GHz)(Filter Mode)+12dBm(10~50MHz)(High Power
+7dBm(10~50MHz)(High PowerMode)
Max. Output Power (Option 201,

401,

402)

 

Port 1, 3

Mode)

+4dBm(0.05~4GHz)(High Power Mode)

+3dBm(4~13.5GHz)

+5dBm(13.5~40GHz)

+2dBm(40~47GHz)

-10dBm(47~50GHz)

+8dBm(0.05~4GHz)(High Power Mode)

+9dBm(4~13.5GHz)

+12dBm(13.5~40GHz)

+9dBm(40~47GHz)

-1dBm(47~50GHz)

Port 2, 4+10dBm(10~50MHz)

+8dBm(0.05~4GHz)

+4dBm(4~13.5GHz)

+15dBm(10~50MHz)

+14dBm(0.05~4GHz)

+12dBm(4~13.5GHz)

 

+5dBm(13.5~40GHz)

+2dBm(40~47GHz)

-10dBm(47~50GHz)

+11dBm(13.5~40GHz)

+8dBm(40~47GHz)

-2dBm(47~50GHz)

1dB Compression Level 

/

 

+10dBm

Pulse CharacteristicTypical Value
Pulse         Width Setting Range33ns~60s20ns~60s
Pulse Transition Time

(10%-90%)

 

30ns

 

20ns

Pulse        On/Off Ratio64dB(0.01~4GHz)

80dB(4~40GHz)

80dB(40~50GHz)

Network Parameter CharacteristicsTypical Value
74dB(0.01~1GHz)105dB(0.01~1GHz)
119dB(1~13.5GHz)133dB(1~13.5GHz)
System Dynamic Range115dB(13.5~26.5GHz)

110dB(26.5~35GHz)

126dB(13.5~26.5GHz)

120dB(26.5~35GHz)

105dB(35~47GHz)116dB(35~47GHz)
90dB(47~50GHz)103dB(47~50GHz)
Effective Directivity42dB(0.01~13.5GHz)

38dB(13.5~40GHz)

36dB(40~50GHz)

50dB(0.01~13.5GHz)

45dB(13.5~40GHz)

42dB(40~50GHz)

36dB(0.01~2GHz)43dB(0.01~2GHz)
Effective Source Match31dB(2~13.5GHz)

28dB(13.5~40GHz)

34dB(2~13.5GHz)

33dB(13.5~40GHz)

27dB(40~50GHz)33dB(40~50GHz)
Effective     Load Match42dB(0.01~13.5GHz)

37dB(13.5~40GHz)

35dB(40~50GHz)

60dB(0.01~13.5GHz)

56dB(13.5~40GHz)

51dB(40~50GHz)

Reflection Tracking±0.04dB(0.01~13.5GHz)

±0.03dB(13.5~40GHz)

±0.04dB(40~50GHz)

±0.010dB(0.01~13.5GHz)

±0.010dB(13.5~40GHz)

±0.020dB(40~50GHz)

Transmission Tracking±0.1dB(0.01~13.5GHz)

±0.16dB(13.5~40GHz)

±0.20dB(40~50GHz)

±0.012dB(0.01~13.5GHz)

±0.015dB(13.5~40GHz)

±0.020dB(40~50GHz)

OthersTypical Value
Amplitude Trace0.050(10~50MHz)

0.020(50~500MHz)

0.005(0.5~13.5GHz)

0.004(13.5~26.5GHz)

0.008(26.5~50GHz)

0.0060(10~50MHz)

0.0020(50~500MHz)

0.0010(0.5~13.5GHz)

0.0009(13.5~26.5GHz)

0.0040(26.5~50GHz)

Noise
dB rms(1kHz IF
Bandwidth)
Phase          Trace0.900(10~50MHz)

0.700(50~500MHz)

0.040(0.5~13.5GHz)

0.050(13.5~26.5GHz)

0.060(26.5~50GHz)

0.040(10~50MHz)

0.010(50~500MHz)

0.005(0.5~13.5GHz)

0.020(13.5~26.5GHz)

0.030(26.5~50GHz)

Noise
deg rms (1kHz IF
Bandwidth)
IF Bandwidth1Hz~5MHz
Amplitude Display0.001dB/div

 

Resolution
Phase       Display Resolution0.01°/div
Setting Requirement     of Reference    Level Amplitude 

-500~+500dB

Setting Requirement     of Reference    Level

Phase

 

-500~+500°

General Characteristic
Port Connectors2.4mm (Male), 50 ohm system impedance
Number            of Measuring Ports3672C/D Standard configuration:2 ports, 3672C/D-400 Option: 4 ports
Peripheral

Interface

USB, GPIB, VGA, LAN
Operating SystemWindows 7
Display12.1-Inch High Resolution Touch Screen
SizeW´H´D=426mm×266mm×600mm (excluding support and handle) W´H´D=516mm×280mm×690mm (including handle, support and back foot)
Max.          Power

Consumption

500w
Max. Weight47kg

 

3672E Technical Specifications

Frequency Characteristics
Frequency Range10MHz~67GHz
Frequency Resolution1Hz
Frequency

Accuracy

±1×10-7(23℃±3℃)
Port Harmonic SuppressionTypical Value
Harmonic Suppression     on Port 1 and 3-48dBc(0.01~4GHz)

-57dBc(4~67GHz)

-51dBc(0.01~4GHz)

-60dBc(4~67GHz)

Harmonic Suppression     on Port 2 and 4-13dBc(0.01~4GHz)

-18dBc(4~13.5GHz)

-57dBc(13.5~67GHz)

-13dBc(0.01~4GHz)

-21dBc(4~13.5GHz)

-60dBc(13.5~67GHz)

Port Power CharacteristicsTypical Value
 

 

Power       Sweep Range

32dB(10~50MHz)

29dB(0.05~4GHz)

28dB(4~26.5GHz)

29dB(26.5~35GHz)

26dB(35~40GHz)

25dB(40~67GHz)

42dB(10~500MHz)

38dB(0.5~4GHz)

36dB(4~26.5GHz)

35dB(26.5~35GHz)

34dB(35~40GHz)

32dB(40~67GHz)

 

 

 

 

Max. Output Power (standar d configur ation, option 400)

 

 

 

 

Port 1, 3

-1dBm(10~50MHz)(Filter mode) 0dBm(0.05~4GHz)(Filter mode)

+8dBm(10~50MHz)(High power mode)

+5dBm(0.05~4GHz )( High power mode)

+1dBm(4~13.5GHz)

+5dBm(13.5~26.5GHz)

+3dBm(26.5~40GHz)

+5dBm(40~67GHz)

 

+16dBm(10~50MHz)(High power mode)

+10dBm(0.05~4GHz)(High power mode)

+9dBm(4~13.5GHz)

+11dBm(13.5~26.5GHz)

+10dBm(26.5~40GHz)

+9dBm(40~67GHz)

 

 

Port 2, 4

+8dBm(10~50MHz)

+5dBm(0.05~4GHz)

+1dBm(4~13.5GHz)

+5dBm(13.5~26.5GHz)

+3dBm(26.5~40GHz)

+5dBm(40~67GHz)

+16dBm(10~50MHz)

+15dBm(0.05~4GHz)

+10dBm(4~13.5GHz)

+11dBm(13.5~26.5GHz)

+9dBm(26.5~40GHz)

+8dBm(40~67GHz)

 

 

 

 

Max. Output Power (option 201,

401,

402)

 

 

 

 

Port 1, 3

-2dBm(10~50MHz)(Filter Mode)

-1dBm(0.05~4GHz)(Filter Mode)

+7dBm(10~50MHz)(High Power Mode)

+4dBm(0.05~4GHz)(High Power Mode)

-2dBm(4~13.5GHz)

+3dBm(13.5~26.5GHz) 0dBm(26.5~67GHz)

 

+15dBm(10~50MHz)(High Power Mode)

+9dBm(0.05~4GHz)(High Power Mode)

+6dBm(4~13.5GHz)

+7dBm(13.5~26.5GHz)

+4dBm(26.5~67GHz)

 

Port 2, 4

+7dBm(10~50MHz)

+4dBm(0.05~4GHz)

-2dBm(4~13.5GHz)

+3dBm(13.5~26.5GHz) 0dBm(26.5~67GHz)

+15dBm(10~50MHz)

+14dBm(0.05~4GHz)

+9dBm(4~13.5GHz)

+10dBm(13.5~26.5GHz)

+5dBm(26.5~67GHz)

 

1dB

Compression Level

 

/

 

+10dBm

Pulse CharacteristicsTypical Value
Pulse         Width Setting Range33ns~60s20ns~60s
Pulse Transition Time (10%-90%)30ns20ns
Pulse Ratioon/off64dB(0.01~4GHz)

80dB(4~67GHz)

Network Parameter CharacteristicTypical Value
74dB(0.01~1GHz)100dB(0.01~1GHz)
100dB(1~4GHz)125dB(1~4GHz)
System Dynamic Range120dB(4~10GHz)

112dB(10~26.5GHz)

108dB(26.5~35GHz)

125dB(4~10GHz)

120dB(10~26.5GHz)

115dB(26.5~35GHz)

105dB(35~50GHz)112dB(35~50GHz)
100dB(50~67GHz)105dB(50~67GHz)
35dB(0.01~2GHz)50dB(0.01~2GHz)
Effective Directivity41dB(2~13.5GHz)

34dB(13.5~40GHz)

50dB(2~13.5GHz)

50dB(13.5~40GHz)

32dB(40~67GHz)42dB(40~67GHz)
35dB(0.01~2GHz)60dB(0.01~2GHz)
Effective MatchLoad41dB(2~13.5GHz)

33dB(13.5~40GHz)

50dB(2~13.5GHz)

50dB(13.5~40GHz)

30dB(40~67GHz)45dB(40~67GHz)
±0.05dB(0.01~2GHz)±0.005dB(0.01~2GHz)
Reflection Tracking±0.06dB(2~13.5GHz)

±0.08dB(13.5~40GHz)

±0.005dB(2~13.5GHz)

±0.008dB(13.5~40GHz)

±0.10dB(40~67GHz)±0.010dB(40~67GHz)
±0.10dB(0.01~2GHz)±0.005dB(0.01~2GHz)
Transmission Tracking±0.11dB(2~13.5GHz)

±0.16dB(13.5~40GHz)

±0.006dB(2~13.5GHz)

±0.015dB(13.5~40GHz)

±0.20dB(40~67GHz)±0.020dB(40~67GHz)
OthersTypical Value
Amplitude Trace0.050(10~50MHz)

0.020(50~500MHz)

0.005(0.5~13.5GHz)

0.004(13.5~26.5GHz)

0.020(26.5~67GHz)

0.0090(10~50MHz)

0.0020(50~500MHz)

0.0008(0.5~13.5GHz)

0.0008(13.5~26.5GHz)

0.0050(26.5~67GHz)

Noise
dB rms(1kHz IF
bandwidth)
PhaseTrace0.90(10~50MHz)

0.70(50~500MHz)

0.04(0.5~13.5GHz)

0.05(13.5~26.5GHz)

0.10(26.5~67GHz)

0.010(10~50MHz)

0.010(50~500MHz)

0.006(0.5~13.5GHz)

0.007(13.5~26.5GHz)

0.030(26.5~67GHz)

Noise
deg rms(1kHz IF
bandwidth)
IF Bandwidth1Hz~5MHz
Amplitude Display Resolution 

0.001dB/div

Phase       Display

Resolution

0.01°/div
Setting-500~+500dB

 

Requirement     of

Reference    Level Amplitude

Setting Requirement     of

Reference    Level Phase

 

-500~+500°

General Characteristics
Port Connectors1.85mm (Male), 50 ohm system impedance
Number           of measuring Ports3672E Standard configuration:2 ports, 3672E-400 Option: 4 ports
Peripheral InterfaceUSB, GPIB, VGA, LAN
Operating SystemWindows 7
Display12.1-Inch High Resolution Touch Screen
SizeW´H´D=426mm×266mm×600mm (excluding support and handle) W´H´D=516mm×280mm×690mm (including handle, support and back foot)
Max.          Power

Consumption

500W
Max. Weight50 kg

 

Ordering Information 

Main UnitDescription
3672AVector Network Analyzer (10MHZ ~ 13.5GHZ)
3672BVector Network Analyzer (10MHZ ~ 26.5GHZ)
3672CVector Network Analyzer (10MHZ ~ 43.5GHZ)
3672DVector Network Analyzer (10MHZ ~ 50GHZ)
3672EVector Network Analyzer (10MHZ ~ 67GHZ)

 Standard Package

No.DescriptionRemarks
1Power Cord AssemblyStandard three-prong power cord
2USB Keyboard/Mouse
3User Manual
4Certificate of Conformity
5Aluminum Alloy Box

 Options

3672A Options

ModelDescriptionRemarks
 3672A-2012-Port      Programmable      Step AttenuatorSet two 70dB programmable step attenuators for the source path, and two 35dB programmable step attenuators for the receiver path
3672A-4004-Port MeasurementTwo-source

configuration

stimulusfour-portVNA
 3672A-401 4-Port      Programmable      Step AttenuatorSet four 70dB programmable step attenuators for the source path, and four 35dB programmable step attenuators for the receiver path (Option 400 is needed)
3672A-402Active               Inter-modulation MeasurementFor inter-modulation signal measurement of amplifier (Option 400 is needed)
3672A-006English OptionsKey, Front Panel, Label, Operation System
3672A-008Pulse MeasurementFor pulse S-parameter measurement
 3672A-S10 Time Domain MeasurementFor time-domain test, can locate and analyze the discontinuous positions in devices, fixtures or cables.
 3672A-S80 Frequency Offset MeasurementFor frequency offset measurement. millimeter-wave frequency extension main unit needs this option
3672A-S82Mixer Scalar MeasurementFor the scalar parameter measurement of mixers (Option 400 is needed)
3672A-S83Mixer Vector MeasurementFor the vector parameter measurement of mixers (Option 400 is needed)
3672A-S84Embedded LO Frequency

Converter Measurement

For the measurement of embedded LO frequency converters (Option 400, S82 or S83 are needed)
 3672A-S86Gain Compression Two-Dimension Sweep MeasurementFor the gain compression two-dimension sweep test of amplifier
311213.5mm Calibration KitFor calibration of the analyzer
FB0HA0HB025.03.5mm Test cableFor measurement of the analyzer
FB0HA0HC025.03.5mm Test cableFor measurement of the analyzer
20403E-Cal KitFor        calibration        of        the        analyzer (10MHz-26.5GHz, 2 ports)
20405E-Cal KitFor calibration of the analyzer (10MHz-20GHZ, 4 ports)
87232Usb Power ProbeFor 402, S82, S86 Options in the process of

power calibration(50MHz-26.5GHZ)

3672B Options

ModelDescriptionRemarks
 3672B-2012-Port      Programmable      Step AttenuatorSet Two 70dB programmable step attenuators for the source path, and two 35dB programmable step attenuators for the receiver path
3672B-4004-Port MeasurementTwo-source

configuration

stimulusfour-portVNA
 3672B-401 4-Port      Programmable      Step AttenuatorSet four 70dB programmable step attenuators for the source path, and four 35dB programmable step attenuators for the receiver path (Option 400 is needed)
3672B-402Active               Inter-modulation MeasurementFor inter-modulation signal measurement of amplifier (Option 400 is needed)
3672B-006English OptionsKey, Front Panel, Label, Operation System
3672B-008Pulse MeasurementFor pulse S-parameter measurement
 3672B-S10 Time Domain MeasurementFor time-domain test, can locate and analyze the discontinuous positions in devices, fixtures or cables.
 3672B-S80 Frequency Offset MeasurementFor frequency offset measurement. millimeter-wave frequency extension main unit needs this option
3672B-S82Mixer Scalar MeasurementFor the scalar parameter measurement of mixers (Option 400 is needed)
3672B-S83Mixer Vector MeasurementFor the vector parameter measurement of mixers (Option 400 is needed)
3672B-S84Embedded       LO       Frequency Converter MeasurementFor the measurement of embedded LO frequency converters(Option 400, S82 or S83 are needed)
 3672B-S86Gain Compression Two-Dimension Sweep MeasurementFor the gain compression two-dimension sweep test of amplifier
311213.5mm Calibration KitFor calibration of the analyzer
FB0HA0HB025.03.5mm Test cableFor measurement of the analyzer
FB0HA0HC025.03.5mm Test cableFor measurement of the analyzer
20403E-Cal KitFor        calibration        of        the        analyzer (10MHZ-26.5GHZ, 2 ports)
20405E-Cal KitFor calibration of the analyzer (10MHZ-20GHZ, 4 ports)
87232USB Power ProbeFor 402, S82, S86 Options in the process of

power calibration(50MHZ-26.5GHZ)

3672C Options

ModelDescriptionRemarks
 3672C-2012-Port      Programmable      Step AttenuatorSet two 60dB programmable step attenuators for the source path, and two 35dB programmable step attenuators for the receiver path
3672C-4004-Port MeasurementTwo-source

configuration

stimulusfour-portVNA
 3672C-401 4-Port      Programmable      Step AttenuatorSet four 60dB programmable step attenuators for the source path, and four 35dB programmable step attenuators for the receiver path (Option 400 is needed)
3672C-402Active Inter-modulation MeasurementFor inter-modulation signal measurement of amplifier (Option 400 is needed)
3672C-006English OptionsKey, Front Panel, Label, Operation System
3672C-008Pulse MeasurementFor pulse S-parameter measurement
 3672C-S10 Time Domain MeasurementFor time-domain test, can locate and analyze the discontinuous positions in devices, fixtures or cables.
 3672C-S80 Frequency Offset MeasurementFor frequency  offset measurement. millimeter-wave frequency extension main unit needs this option
3672B-S82Mixer Scalar MeasurementFor the scalar parameter measurement of mixers (Option 400 is needed)
3672B-S83Mixer Vector MeasurementFor the vector parameter measurement of mixers (Option 400 is needed)
3672B-S84Embedded LO Frequency

Converter Measurement

For the measurement of embedded LO frequency converters (Option 400, S82 or S83 are needed)
 3672C-S86Gain Compression Two-Dimension Sweep MeasurementFor the gain compression two-dimension sweep test of amplifier
311232.4mm Calibration KitFor calibration of the analyzer
FE0BN0BM025.02.4mm Test cableFor measurement of the analyzer
FE0BN0BL025.02.4mm Test cableFor measurement of the analyzer
20404E-Cal KitFor calibration of the analyzer (10MHz-50GHz 2 ports)
87233USB Power ProbeFor 402, S82, S86 Options in the process of power calibration (50MHz-40GHz)

3672D Options

ModelDescriptionRemarks
 3672D-2012-Port      Programmable      Step AttenuatorSet two 60dB programmable step attenuators for the source path, and two 35dB programmable step attenuators for the receiver path
3672D-4004-Port MeasurementTwo-source configurationstimulusfour-portVNA
 3672D-401 4-Port      Programmable      Step AttenuatorSet four 60dB programmable step attenuators for the source path, and four 35dB programmable step attenuators for the receiver path (Option 400 is needed)
3672D-006English OptionsKey, Front Panel, Label, Operation System
3672D-008Pulse MeasurementFor pulse S-parameter measurement
 3672D-S10 Time Domain MeasurementFor time-domain test, can locate and analyze the discontinuous positions in devices, fixtures or cables.
 3672D-S80 Frequency Offset MeasurementFor frequency offset measurement. millimeter-wave frequency extension main unit needs this option
3672B-S82Mixer Scalar MeasurementFor the scalar parameter measurement of mixers (Option 400 is needed)
3672B-S83Mixer Vector MeasurementFor the vector parameter measurement of mixers (Option 400 is needed)
3672B-S84Embedded       LO       Frequency Converter MeasurementFor the measurement of embedded LO frequency converters(Option 400, S82 or S83 are needed)
 3672D-S86Gain Compression Two Dimension Sweep MeasurementFor the gain compression two-dimension sweep test of amplifier
31123A2.4mm Calibration KitFor calibration of the analyzer
FE0BN0BM025.02.4mm Test cableFor measurement of the analyzer
FE0BN0BL025.02.4mm Test cableFor measurement of the analyzer
20404E-Cal KitFor calibration of the analyzer (10MHZ-50GHZ 2 ports)

3672E Options

ModelDescriptionRemarks
 3672E-2012-Port     Programmable     Step AttenuatorSet two 50dB programmable step attenuators for the source path, and two 50dB programmable step attenuators for the receiver path
3672E-4004-Port MeasurementTwo-source stimulus four-port VNA configuration
 

3672E-401

 

4-Port     Programmable     Step Attenuator

Set four 50dB programmable step attenuator s for the source path, and four 50dB programmable step attenuator s for the receiver path (Option 400 is needed)
3672E-402Active             Inter-modulation MeasurementFor inter-modulation signal measurement of amplifier (Option 400 is needed)
3672E-006English OptionsKey, Front Panel, Label, Operation System
3672E-008Pulse MeasurementFor pulse S-parameter measurement
 

3672E-S10

 

Time-Domain Measurement

For time-domain test, can locate and analyze the discontinuous positions in devices, fixtures or cables.
 

3672E-S80

 

Frequency Offset Measurement

For frequency offset measurement. millimeter-wave frequency extension main unit needs this option
3672E-S82Mixer Scalar MeasurementFor the scalar parameter measurement of mixers (Option 400 is needed)
3672E-S83Mixer Vector MeasurementFor the vector parameter measurement of mixers (Option 400 is needed)
3672E-S84Embedded  LO Frequency Converter MeasurementFor the measurement of embedded LO frequency converters(Option 400, S82 or S83 are needed)
 

3672E-S86

Gain Compression Two-Dimension  Sweep MeasurementFor the gain compression two-dimension sweep test of amplifier
311281.85mm Calibration KitFor calibration of the analyzer
N4697F/ FF0CN0CM025.0

FF0CN0CL025.0

 

1.85mm Test cable

 

For measurement of the analyzer

20409E-Cal KitFor calibration of the analyzer (10MHZ-67GHZ, 2 ports)

 

 

 