3010A Multiproduct Calibrator + ISO 17025 accreditation

Calibrators supplied ready to use, including

  • ISO-17025 Accredited Calibration Certificate (Calibrator + Options), Basic Test Lead Set,
  • 1x USB Lead (main unit), 1x Serial COM Lead (Adapter Interface), Operation Manual, Power Cord
  • 3 Year Warranty as standard

Calibrators & Options Supplied complete with ISO-17025 Accredited Certification

SKU: 3010A Category:
Brands:
Brands

Description

3010A Multiproduct Calibrator + ISO 17025 accreditation

Calibrators supplied ready to use, including

  • ISO-17025 Accredited Calibration Certificate (Calibrator + Options), Basic Test Lead Set,
  • 1x USB Lead (main unit), 1x Serial COM Lead (Adapter Interface), Operation Manual, Power Cord
  • 3 Year Warranty as standard

Calibrators & Options Supplied complete with ISO-17025 Accredited Certification

3010A Key Features

All features of the 3000 Plus…

  • 0 – 1000V DC / AC Voltage
  • 0 – 30A DC / AC Current
  • 0 – 1 GOhm Resistance
  • 1nF – 10mF Capacitance
  • 1Hz – 10MHz Frequency
  • Range of external accessories to increase workload

 

 

 

 

 

 

 

 

 

 

Description

The 3000A Series multiproduct calibrators have been designed to help you and your business, allowing a wide range of calibration work to be performed quickly, accurately and economically. Modern calibration is a competitive market, and cost effective equipment and software are key considerations.

The 3000A Series calibrators offer the widest workload coverage of any calibration system presently available. The unique concept of external calibration adapters, combined with built-in measurement capability, dramatically extends the range of instruments that can be cost-effectively calibrated.

Consisting of 3 models ranging from 8ppm to 50ppm, the 3000A Series Multiproduct Calibrator provides a solution for your laboratory workload requirements.

 

 

 

 

 

 

 

 

 

 

Wide Workload Coverage

The 3000 series offers the widest workload coverage of any multi-product calibrator, with the ability to calibrate 18 types of instrument. It has the power to drive older analogue instruments alongside the accuracy to calibrate modern digital instruments.

The 3000 series features three models designed to suit every budget and accuracy requirement, and with a wide range of options that allow your calibrator to be tailored to meet your needs, the 3000 series is expandable for future needs.

AUTOMATED CALIBRATION

Automate calibration with Procal – the world’s easiest to use multi-discipline calibration software for maximum calibration throughput.

SOFTWARE COMPATIBILITY

As with all Transmille products, compatibility with ProCal calibration software is guaranteed. Existing procedures will not need to be re-written, due to Transmille’s unique implementation of flexible standards support where procedures are written around the UUT, not the standard.

3000A Service Guide – Entering Calibration Mode

In this video, we show how to enter the calibration mode of the 3000A series multiproduct calibrator from the front panel.

3000A Service Guide – Adjusting DC Voltage

In this video we show how to adjust the DC voltage output of the 3000A series multiproduct calibrator. Using the guided calibration mode this is a simple procedure, which can be performed in just a few minutes.

3000A Service Guide – Adjusting AC Voltage

In this video we demonstrate how to adjust the AC voltage output of the 3000A series multiproduct calibrator.

3000A Service Guide – Output Protection Fuse Replacement

In this video we show how to diagnose and replace the front panel output protection fuses on the 3000A series calibrator.

How To – Calibrate a Multimeter with the 3000A Calibrator

In this video we demonstrate how to verify key features of a typical digital multimeter using a 3010A Multiproduct Calibrator.

3000 Series – PWRDDS Video

Demonstration of the PWRDDS Option.

 

 

 

 

 

 

Additional information

Weight 12.5 kg
Dimensions 14 × 43 × 46 cm

Specifications

User Manuals

Application Notes

 

ALL MODELS

CHOOSE THE PERFECT MODEL

3050A MODEL

3041A MODEL

3010A MODEL

DC Voltage
Best 1 Year Total Accuracy
0 – ±1000V
±8 ppm50
0 – ±1000V
±25 ppm
0 – ±1000V
±8 ppm
DC Current
Best 1 Year Total Accuracy
0 – ±22A
±100 ppm
0 – ±30A
±50 ppm
0 – ±30A
±50 ppm
AC Voltage
Best 1 Year Total Accuracy
20mV – 1000V, 10Hz – 100kHz 20mV – 1000V, 10Hz – 100kHz
0.04%
20mV – 1000V, 10Hz – 1MHz
±0.15%
AC Current
Best 1 Year Total Accuracy
20uA – 22A, 10Hz – 10kHz
±0.07%
20uA – 30A, 10Hz – 10kHz
±0.06%
20uA – 30A, 10Hz – 10kHz
±0.04%
Resistance (Passive)
Best 1 Year Total Accuracy
0 Ohms – 100 Ohms
60 ppm
0 Ohms – 1 GOhm
40 ppm
0 Ohms – 1 GOhm
18 ppm
Capacitance (Passive)
Best 1 Year Total Accuracy
10nF – 1uF
0.25%
1nF – 10uF
0.25%
1nF – 10uF
0.25%
Frequency
Best 1 Year Total Accuracy
11Hz – 10MHz
20 ppm
1Hz – 10MHz
20 ppm (1 ppm option)
1Hz – 10MHz
20 ppm (1 ppm option)
Temperature (Thermocouple)
Best 1 Year Total Accuracy
J,K,T,R,S,B,U,N,E,L,U,C
10uV°C
J,K,T,R,S,B,U,N,E,L,U,C
10uV°C
J,K,T,R,S,B,U,N,E,L,U,C
10uV°C

Internal Options (Choose At Time Of Order)


PRT/RTD Temperature Simulation (Option PRT, Included in -SYS Models)

The PRT option simplifies calibration of high-accuracy resistance thermometers. Reliable readings are guaranteed regardless of measurement technique, because the calibrator uses passive precision resistors.When the PRT option is calibrated, the precise temperature values on the ITS-90 scale for PT-385 resistors are stored in the memory.  The values can be recalled and displayed every time a specific resistor is chosen, to allow accurate calibration.

When combined with the SIMRC option, an additional 2-Wire variable output is available, which enables simulation of any value.


Simulated Resistance & Capacitance (Option SIMRC, Included in -SYS Models)

This option allows for resistance calibration between cardinal points. It has a continuous resistance range between 0 Ohms and 1 GOhms, with variable capacitance from 0.95uF to 100mF.

This option enables calibration of multimeters with non-decade calibration points.


Inductance Calibration Option (IND)

Simulated Resistance & Capacitance

This option allows for resistance calibration between cardinal points. It has a continuous resistance range between 0 Ohms and 1 GOhms, with variable capacitance from 0.95uF to 100mF.

This option enables calibration of multimeters with non-decade calibration points.


High Stability Frequency Output (Option FRQ)

The FRQ option is available for the 4015.  It is a 1 ppm high-stability frequency output, for calibrating high accuracy frequency counters.

The FRQ option reduces equipment requirements for the calibration of hand-held frequency counters, and removes the need to install 10MHz distribution throughout the laboratory or workshop.


Oscilloscope Calibration (Option SCP)

  • Advanced oscilloscope calibration option, adding the ability to calibrate oscilloscopes to your multiproduct calibrator.
  • Waveforms for amplitude, timebase, rise time, and bandwidth are provided, with outputs up to 300V pk-pk.
  • SCP250 enables calibration of oscilloscopes up to 250 MHz.
  • SCP350 enables calibration of oscilloscopes up to 350 MHz.
  • SCP600 enables calibration of oscilloscopes up to 600 MHz.

(Option PWRSINE and PWRDDS)

The PWRSINE option enables cost-effective calibration of power (watts) and VA ranges on power meters and clamp meters with power measurement functions. The PWRSINE option provides variable voltage and current simultaneously, with an accurately adjustable phase relationship.

The PWRDDS option enables cost-effective calibration of power (watts) and VA ranges on power meters and clamp meters with power measurement functions. The PWRDDS option provides variable voltage and current simultaneously with an accurately adjustable phase relationship. In addition to the functions provided by PWRSINE, PWRDDS enables harmonics and distortion to be added to the power output for calibration of power quality functions of advanced power meters.

Pre-programmed harmonics are loaded into memory, with custom waveform shapes able to be loaded into the calibrator through the included computer software for completely customized testing with waveforms with custom harmonic content.

 

For both PWRSINE and PWRDDS:

Any voltage up to 1025V can be set, with a maximum current output of 30A without the need for external current amplifiers, allowing up to 1.5MW of power to be simulated.

The power function is very easy to use through intuitive menu design. Simply select ‘Power’ from the calibrator menu, enter the required parameters and connect the power meter to the indicated terminals. Voltage, current, frequency and phase can all be entered using the numerical keyboard, with phase angle adjustable to a resolution of 0.1°.

Power output is automatically calculated, and power factor and apparent power are also displayed on the screen automatically for quick comparis


External Adaptors and Accessories (Add Anytime)


Thermocouple Simulation & Measurement Adapter (EA001A)

For the ultimate in accuracy, Transmille has designed a dedicated source/measure external adapter. This keeps the electronics required to generate the low-level signals used for thermocouple simulation as close as possible to the measuring input of the thermometer, which also allows the signal to be as free from electrical noise as possible, and eliminates errors caused by heat from surrounding electronics.

The cold junction compensation (CJC) sensor is mounted in the thermocouple plug itself. By measuring the cold junction at the instrument’s input, you can simulate any type of thermocouple without using thermocouple compensation cables.

Features

  • Enables fast and accurate calibration of thermocouple meters
  • Uses an innovative external measurement of cold junction temperature for ultimate accuracy
  • Utilizing a thermocouple plug removes the requirement for expensive thermocouple compensation cable

Option Documentation

EA001A Operation Manual
EA001A Extended Specifications
EA001A Calibration Guide


2/10/50 Turn Coil Adapter (EA002)

The Transmille EA002 offers several unique features.

Robust construction allows for years of hard use without risking damage to the coil.  An included alignment table ensures repeatable results.  This option was designed for the calibration of wound AC and magnetic field hall effect AC/DC clamp meters.

Features

  • Calibrates clamp meters up to 1500A (30A input)
  • Wide range of clamp sizes covered
  • 2/10/50 Turn Coils
  • High accuracy AC/DC design, with minimal errors due to alignment
  • Alignment table included for accurate and repeatable readings

Option Documentation

EA002 Operation Manual

EA002 Extended Specifications
Understanding-Coil-Calibration-Uncertainties
EA002—Precision-Clamp-Coil-Adapter


Optical Tachometer Calibration Adapter (EA003)

Optical adapters can be calibrated quickly and easily, thanks to a high-intensity LED light source. Using the keypad, or ProCal software for automated calibration, simply enter the RPM value. With a range of 60 – 60,000 RPM, the EA003 can calibrate a whole range of optical tachometers.

Features

  • High-intensity LED light source
  • Direct keyboard input in RPM
  • Control via ProCal for fully automated calibration
  • Output range from 60 to 60,000 RPM

Option Documentation

EA003 Operation Manual

EA003 Extended Specifications
EA003 Sample ISO-17025 Calibration Certificate


High Resistance/pA Measurement Adapter (EA008)

This option eliminates the need for a separate electrometer. The low-cost EA008 provides five current measurement ranges, down to 10nA, with a resolution of 1pA. It also incorporates a ‘virtual ground’ input, avoiding input impedance errors.

The EA008 allows high-accuracy resistance measurements at any voltage up to 1000V, with the high voltage output from the 4000 Series calibrators.

Features

  • Accurate current measurement down to 1pA resolution
  • Ideal for high value resistance measurements up to 1 TOhm
  • High resistance measurement voltages up to 1000V
  • 5 current measurement rnages from 10nA to 100uA
  • Control directly from the calibrator front panel or use with ProCal software

Option Documentation

EA008-Operation-Manual
EA008-Extended-Specifications


100A DC/70A AC Transconductance Amplifier (EA3012A)

The EA3012A is a powerful linear transconductance amplifier designed for use with Transmille calibrators to provide a cost-effective solution for generation of high currents.

The EA3012A connects directly to the adapter input connector on the front of Transmille calibrators and is controlled directly via the front panel with output in terms of Amps, or can be automated through ProCal calibration software.

Higher currents are available by paralleling multiple EA3012A amplifiers to reach currents in excess of 300A.

Features

  • 100 DC/70A AC up to 400Hz
  • Stackable for higher currents
  • Low-noise ultra linear MOSFET technology
  • Controlled directly via front panel of calibrator
  • Automation through ProCal software
  • Ideal for calibrating high current shunts, meters and clamp meters

Option Documentation

EA3012-Operation-Manual-V4-00-May-2018
EA3012A-Extended-Specifications


High Resistance/pA Measurement Adapter (EA013)

This option eliminates the need for a separate electrometer. The low-cost EA008 provides five current measurement ranges, down to 10nA, with a resolution of 1pA. It also incorporates a ‘virtual ground’ input, avoiding input impedance errors.

The EA008 allows high-accuracy resistance measurements at any voltage up to 1000V, with the high voltage output from the 4000 Series calibrators.

Features

  • Ideal for calibration of electrometer instruments
  • Source accurate current down to picoamp levels
  • Low open circuit compliance voltage
  • Safe to use on sensitive input circuits
  • Controlled directly from the calibrator front panel or via supplied software
  • Compatible with ProCal for full measurement automation

Option Documentation

EA013-Extended-Specifications
EA013—pA-Source-Adapter—Example-Certificate

 


Torque Calibration Adapter (EA014)

Connecting the EA014 to your Transmille calibrator adds torque calibration capabilities to your laboratory in a cost-effective way.

An external torque transducer allows you to calibrate torque screwdrivers up to 10Nm, with a range of torque transducers from 1Nm to 1500Nm.


Multi-Function Workstation (EA015)

The Multi-Function Workstation is a central work area, where all connections are conveniently routed to terminals mounted on the adapter front.

This workstation provides a versatile platform for efficient calibration of equipment, incorporating the advanced clamp coil, thermocouple simulation and tachometer calibration adapters.  It also includes process control source/measure capabilities.

Features

  • Insulation Testers
  • Continuity Testers
  • Optical Tachometers
  • Thermocouple Meters
  • Clamp Meters
  • Source functions of process control meters

Option Documentation

EA015-Operation-Manual-V1-10
EA015-Extended-Specifications
EA015—Workstation-Adapter—Example-Certificate


Temperature & Humidity Monitoring Adapter (EA016)

The EA016 allows measurement of the local temperature and humidity for recording on certificates and test reports.

Working on-site makes it essential to maintain accurate calibration records.  The EA016 avoids the requirement of humidity/temperature probes.

Features

  • Humidity measurement from 10% to 90%
  • Temperature measurement from 0°C to 50°C

Option Documentation

EA016-Example-Certificate


4-Channel Oscilloscope Test Head Adapter (EA017)

The EA017 provides a 4-channel switching test head for automation of oscilloscope calibration.

You can easily select a low impedance buffered amplitude output for accurate calibration of 50 Ohm output oscilloscopes.

Features

  • 4 Output channels for automating oscilloscope calibration
  • Minimizes lead changing when calibrating oscilloscopes
  • Choose between direct or buffered outputs for amplitude calibration

Option Documentation

EA017-Operation-Guide—web


3A/63V Power Supply Calibration Adapter (EA3023)

The EA3023 is an essential option for simplifying calibration of power supplies. The PSU adapter measures the output voltage, and provides a precision electronic load. This allows volts, current, and even output resistance to be calibrated in one compact unit. Accuracy and dependability are assured through 4-wire connection.

The output resistance of the PSU can be easily measured by measuring the on load/off load voltages of a power supply. Operation is controlled through the virtual front panel software (supplied) or ProCal.

Features

  • Measures voltage up to 63V
  • Active current load to 3A
  • Calculates output resistance of a power supply for complete calibration

Option Documentation

EA3023-Operation-Manual-V1-00
EA3023-Extended-Specifications
EA3023—3A-63V-PSU-Adapter—Example-Certificate


AC/DC Kilovolt Amplifier (EA3024)

The EA3024, with its advanced electronics, is a simple and safe, cost-effective solution for calibration of high voltage probes and dividers.

It can be controlled through dedicated front panel software, or ProCal for safe calibration at high voltages.

Features

  • Outputs from 1kV to 10kV DC
  • Outputs from 1kV to 5kV AC at up to 60Hz
  • Operated using supplied software or via ProCal calibration software

Option Documentation

EA3024-Operation-Manual-V1-00—WEB
EA3024-Extended-Specifications
EA3024–Example-Certificate


60A/60V Power Supply Calibration Adapter (EA3025A)

The EA3025A is an easy-to-use, low-cost solution for calibrating high current power supplies.

An accurate, stable electronic load simulates current load on power supplies, and allows measurement of voltage and output resistance.  It minimizes equipment required for calibrating these common devices.

Features

  • Easy to use, low cost solution
  • Accurate, stable electronic load
  • Minimizes equipment required for calibration

Option Documentation

EA3025A-Extended-Specifications


Hard and Soft Carrying Cases (Options 3XXXTRANS and 3XXXSOFT)

Transit Case

Ideal for transporting to harsh environments such as oil rigs and shipyards, the 3xxx Transit Case provides a safe transportation option for the unit, accessories and manual.

A custom laser cut foam interior ensures the saftey of your investment during shipping.

Fitted with handles and wheels, the 3xxx Transit Case is easy to move and transport.

Soft Case

Designed for carrying your calibrator when working on site, the soft carry case includes side pockets, a large top pocket for leads and a laptop and a carry strap for over arm carrying.

The lightweight construction of the calibrator and soft case allows easy carrying of the unit.

The soft case can be used without removing the unit, as front and rear zip sections unzip to allow access to front and rear panel connections


TPMXX Pressure Modules (TPM001 to TPM018)

A modern calibration laboratory must be able to perform calibration in multiple disciplines in order to remain competitive. Transmille has a range of pressure modules to assist, adding pressure management capability to our products.

Choose from a range of pressure modules that connect directly to our products, and provide read-back directly on-screen.